PIN accepted: yes
PIN count: 3
PUK required: no
GSM network: registered
Operator: T-mobile Austria
Signal quality: 31 99
Phone call: no
GPRS network: registered
IP address: no
TCP connection: no
0
#
ID
D
ESCRIPTION Sets/returns the node’s ID.
PARAMETERS The node ID.
REMARKS GET/SET.
RETURNS The node ID.
REMOTE Yes, SET only.
EXAMPLE # ID 445
42914 ID 0
#
# ID
445 ID 445 0
#
INFO
D
ESCRIPTION Returns various status information.
PARAMETERS None.
REMARKS GET only.
RETURNS A list of a device’s internal variables:
ID INFO rf_in rf_out date time ver clk stack cop batt temp
days_uptime hr:min_uptime rssi pmp_low pmp_high type slot
samples po err_level
#
The formats for the above parameters are as follows:
rf_in and rf_out as a decimal.
date as dd/mm/yyyy.
time as hh:mm:ss.
ver as x.x.