User's Manual

CHAPTER3
UsingTerminalCommands
39
clk, stack, and cop as decimal. They represent internal
housekeeping parameters: the A753 uses cop to number
watchdog occurrences, but clk and stack are currently undefined.
batt as battery level, using the standard voltage conversion
equation (0 is 0 volts, 255 is 20 volts).
temp as internal temperature in the housing, which is device
dependent. The precision of the sensing element is low (±2°C),
but it is sufficient for battery power management (charge/
discharge). To compute the actual value (in °C), the following
equation must be used:
days_uptime in days; with hr:min_uptime, it represents the
amount of time the device is up without a reset or watchdog.
hr:min_uptime in hours:minutes format.
rssi as decimal; it is the programmed value with the RSSI
command.
pmp_low and pmp_high are the programmed values with the PMP
command.
type is used to represent the device type. The following types are
assigned currently:
— 0 for A730MD
— 1 for A720
— 2 for A730SD
— 3 for A720B
— 4 for A733
— 5 for A723
— 6 for A440
— 7 for A733 GSM
— 8 for A731
— 9 for A732
— 10 for A740
— 11 for A740 GSM
— 12 for A724
— 15 for A723_Series 4
— 16 for A724_Series 4
— 21 for A753GSM
slot and samples are the actual values programmed by means of
the SLOT command.
po is the relative output power of the device.
err_level is the error value; 0 means no error.
REMOTE Yes, GET only.
EXAMPLE # 42914 info
42914 info 0 31 01/01/1970 00:00:00 1.2 0 0 0 83 60 0 00:40
Temp
°C[]
internalTemp 400
255
------------------------------------------------- 6 8=