40
0 65 72 24 900 0 0 0
#
PMP
D
ESCRIPTION Sets/returns the node’s Power Management Parameters (switches the
battery charge on/off).
PARAMETERS The lower (switch on) and the higher limit (switch off), both in volts x
10. Standard Values are 65 (for 6.5 volts) for switch on and 72 (for
7.2 volts) for switch off, for a standard 6.2 volt NiMH battery. From
these values, other thresholds are internally computed.
REMARKS GET/SET.
RETURNS The lower (switch on) and the higher limit (switch odd), both in volts x
10.
REMOTE Yes, SET only.
EXAMPLE # PMP 65 72
42914 PMP 0
#
# PMP
42914 PMP 65 72 0
#
ROUTE
NOT AVAILABLE FOR GSM/GPRS-only RTUs
DESCRIPTION Sets/returns the routing information of a device.
PARAMETERS None, or a route (with destination) containing up to eight
intermediaries. When only the destination ID is given, the route for
this device is deleted.
REMARKS GET/SET.
RETURNS The command’s success or error code and the route table.
REMOTE Yes, but only to an A440 attached to an RA440.
EXAMPLE For MFS:
# ROUTE 445 43
442 ROUTE 0
#
# ROUTE
442 ROUTE 445 43 0
#