User's Manual

CHAPTER3
Usingterminalcommands
33
REMARKS Remote only. Support for pre Series 4 RTUs.
RETURNS A pre Series 4 data frame.
REMOTE Yes.
EXAMPLE # 9999 DATA
9999 DATA
13 9 1999 19 26 36 21 37 255 255 79 0 0 0 0 87 148 149 15 0
0 0 0 0 0 0 0 0 3148 0
#
# 9999 DATA 9999 30/9/1999 14:50:00
9999 DATA 30 9 1999 14 54 55 21 37 255 255 77 0 0 0 0 89
156 126 20 0 0 0 0 0 0 0 0 0 3197 0
#
DATASDI
A
VAILABLE FOR A440
DESCRIPTION Retrieves SDI-12 data frames from RTUs earlier than Series 4.
PARAMETERS See the manual for the appropriate pre Series 4 RTU.
REMARKS Remote only. Support for pre Series 4 RTUs.
RETURNS A pre Series 4 data frame.
REMOTE Yes.
EXAMPLE # 12800 DATASDI
12800 DATASDI
16 5 2003 20 14 49 44 60 255 255 127 87 9 0 9 3 0 0
74.379401 3 0 1 68.117003 3 0 2 58.832397 3 0 3 51.611795 3
0 4 38.346400 3 0 5 19.800799 3 0 6 14.895999 3 0 7 3.553500
3 0 8 0.037200 2953 0
#
FDEV
A
VAILABLE FOR RA440
DESCRIPTION Formats the internal memory (might destroy all the data).
0 WARNING The chip configuration setting (first parameter of the command)
depends on the current hardware version and must not be altered.
Please contact our support team for further information.
PARAMETERS If the parameters are missing, the command will show the current
settings. To format the internal memory (all data will be lost) with the
current settings, use 0 as the first parameter. The storage
organization (the index size only), can be optimized for your specific
application. The first parameter for this command is the chip