2
FLEXmax 100 AFCI Specifications 08/2019
www.outbackpower.com
#980-00078-01-00 REV A
Model:
FLEXmax 100 AFCI
Nominal Battery System Voltage
24VDC / 36VDC / 48VDC
Maximum Continuous Output Current
100A
Maximum Input Current (Short-Circuit)
64A
Maximum Array (STC Nameplate)
3500W / 5250W / 7000W (charging output limited to 100A at battery voltage)
Maximum PV System Voltage
300VDC
Operating Input Voltage Range
30 to 290VDC
Standby Power Consumption
~2.5W
Power Conversion Efficiency
24V: 96% 48V: 97%
Peak Efficiency
24V: 97.5% 48V: 98.8%
Charging Regulation
Three-stage
Voltage Regulation Set Points
Absorption, float and equalization
Low power Consumption Mode
Yes, configurable to maximize energy savings based on voltage, time, and current limits
Equalization Charging
Programmable time intervals, voltage set point and duration, automatic termination when completed
Battery Temperature Compensation
Adjustable from 2mV/cell/°C to 6mV/cell/°C
Voltage Step-Down Capability
Down convert from any acceptable array voltage to any battery voltage (example: 72VDC array to 24VDC battery)
Programmable Auxiliary Control Output
12VDC output signal which can be programmed for different control applications (maximum of 0.25ADC)
Status Display
LED indicators
Remote Display and Controller
MATE3s compatible
Network Cabling
Proprietary network system using RJ-45 modular connectors
Data Logging
128 days
Operating Temperature Range
Ambient, –25° to 60°C (–13° to 140°F), output power reduced above 25°C
Ingress Protection Rating
IP54
Enclosure Type
3R
Maximum Altitude Rating
10000ft
Conduit Knockouts
Bottom and sides
Warranty
5 years
Weight (lb/kg)
Unit: 16.0 / 7.3 Shipping: 19.75 / 8.9
Dimensions H × W × D (in/cm)*
Unit: 23 × 8.8 × 6 / 58.4 × 22.4 × 15.2 Shipping: 26 × 12 × 10 / 66 × 30.5 × 25.4
Options
Remote Temperature Sensor (RTS), HUB10.3, MATE3s
Certifications
UL 1741, CSA C22.2 No. 107.1, IEC 62109-1
Minimum Battery Bank Size
100Ah
Charging Range (Output)
20VDC to 68VDC
Additional Features
Built-in and field replaceable arc fault circuit detection and interruption (AFCI), GFCI, and cooling fan
*Height includes fan, not pictured