OutBack Power FLEXMax Series Owner's Manual

Applications
900-0009-01-00 Rev C 101
Figure 102 Adjusting Range Limits for Hydroelectric or Fuel-cell Applications
Charger Aux Light
EQ Misc Advanced
Logging Stats
EXIT GO
Main Menu
Charger Aux Light
EQ Misc Advanced
Logging Stats
EXIT GO
ADV SETUP Screen
ADVANCED MENU
MPPT Mode
Auto Track
EXIT NEXT nonGT MODE
MPPT Mode (Auto Track)
To adjust the Lower Mpp Range Limit:
1. From the main menu, press <> to move the arrow next to
the Advanced function.
2. Press <GO>.
3. In the ADVANCED MENU screen, press <NEXT> again to
display the Mpp Range Limit % Voc screen.
4. Press <1/2> until FULL appears.
5. When finished, press <NEXT> until the MPPT Mode
screen appears.
ADVANCED MENU
Park Mpp
Watts 0251 77 % Voc
EXIT NEXT -% +%
U-
p
ick% (Voc) MPPT
ADVANCED MENU
Mpp Range Limit %VOC
Min Max
EXIT NEXT 1/2 90%
M
pp
Ran
g
e Limit % Vo
c
ADVANCED MENU
Snooze Mode
< 0.6 amp
EXIT NEXT AMP
To pick between
A
uto Track or U-Pick % MPPT Mode and determine the
charge controller’s operating Voc percentage, press <MODE> to interchange
between the two modes.
Re-entering the password might be required. After choosing a mode, press
<NEXT> in the ADVANCED MENU to view the Park Mpp screen (only
applicable for U-Pick mode).
Press < -%> or <+%> to select one of the percentage values; U-Pick always
uses the Park Mpp value.