Outback Power FLEXPower Radian Series Data Sheet

2
OutBack Power Technologies, Inc. 1628 W Williams Drive, Phoenix, AZ 85027
Tel: +1 360 435 6030 Technical Support: +1 360 618 4363 Email: sales@outbackpower.com
For more information visit www.outbackpower.com
© 2020 OutBack Power Technologies, Inc. All Rights Reserved. Trademarks and logos are the property of Alpha Technologies Services, Inc.,
EnerSys and its affiliates unless otherwise noted. Subject to revisions without prior notice. E. & O.E.
FLEXpower Radian
Specifications
Model
*
Description Inverter GSLC Bypass Inverter OCPD
**
PV OCPD
**
GFDI AFCI RTS Charge Controller
FPR-4048A-300AFCI
GS4048A FLEXpower Radian AFCI GS4048A GSLC-PV1-300VDC 120/240VAC 175A 80A Yes Yes Yes (1) FLEXmax 100 AFCI
FPR-4048A-01
GS4048A FLEXpower Radian GS4048A GSLC175-PV1-120/240 120/240VAC 175A 80A Yes No Yes (1) FLEXmax 80
FPR-8048A-300AFCI
GS8048A FLEXpower Radian AFCI GS8048A GSLC-PV-300VDC 120/240VAC (2×) 175A (2×) 80A Yes Yes Yes (2) FLEXmax 100 AFCI
FPR-8048A-300A-LT
GS8048A FLEXpower Radian AFCI Lite GS8048A GSLC-PV1-300VDC 120/240VAC (2×) 175A 80A Yes Yes Yes (1) FLEXmax 100 AFCI
FPR-8048A-01
GS8048A FLEXpower Radian GS8048A GSLC175-PV-120/240 120/240VAC (2×) 175A (2×) 80A Yes No Yes (2) FLEXmax 80
Details
FPR-4048A-300AFCI FPR-4048A-01 FPR-8048A-300AFCI FPR-8048A-300A-LT FPR-8048A-01
Finished Dimensions
H × W × D (in/cm)
47.0 × 33.5 × 9.84 /
119.4 × 85.1 × 24.9
47.0 × 33.5 × 9.84 /
119.4 × 85.1 × 24.9
47.0 × 33.5 × 9.84 /
119.4 × 85.1 × 24.9
47.0 × 33.5 × 9.84 /
119.4 × 85.1 × 24.9
47.0 × 33.5 × 9.84 /
119.4 × 85.1 × 24.9
Weight (lb/kg)
199 / 91 195 / 88.5 258 / 116.4 238 / 107.4 250 / 113.4
Shipping Dimensions
H × W × D (in/cm)
48 ×40 × 18 /
121.9 × 101.6 × 45.7
48 × 40 × 18 /
121.9 × 101.6 × 45.7
48 ×40 × 18 /
121.9 × 101.6 × 45.7
48 ×40 × 18 /
121.9 × 101.6 × 45.7
48 × 40 × 18 /
121.9 × 101.6 × 45.7
Shipping Weight (lb/kg)
218 / 98.6 213 / 96.6 280 / 126.4 260 / 117.4 272 / 123.4
8.0kVA 8.0kW 8.0kVA
6.8kW
Power Rating Notes
Inverters that specify power in VA but do not use the
unity standard Power Factor (PF) could have misleading
power specifications. Volt-Amps (VA) is a total inverter output,
while Watts (W) represent the power consumed by the electrical
loads. PF, which varies by types of loads, is the ratio of W to VA,
and the difference between the two is power in the circuit that
does no useful work. At 1.0PF (unity), all power is used. This is the
industry-standard used by OutBack Power.
Radian GS8048A Power Factor Chart
Power Factor
1.0
0.75
0.5
0.25
0.0
Industry-Standard Non-Industry Standard
0.85
Radian GS8048A Power Rating Chart
Power (VA)
20000
15000
10000
5000
0
100ms 5 sec 30 min continuous
Instantaneous Power Rating
Most stringent, massive load start GS8048A: 16970VA
Surge Power Rating
Less stringent load start GS8048A: 12000VA
Peak Power Rating
Frequent “heavy duty” load requirements GS8048A: 9000VA
Continuous Power Rating
Sustained “real world” load requirements GS8048A: 8000VA
16970VA
12000VA
9000VA
8000VA
Typical Efficiency Rating
Real world efficiency with variable loads GS8048A: 93%
CEC Efficiency Rating
Most stringent US rating GS8048A: 92.5%
Radian GS8048A Efficiency Rating Chart
Efficiency
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
2kVA 4kVA 6kVA 8kVA
92.5%
(CEC)
93% (Typical)
INVERTING SELLING
*All pre-wired systems include a Radian Series inverter/charger, FLEXmax charge controller(s), MATE3s system display and communications, FLEXnet DC system monitor, AC and DC wiring boxes, HUB10.3 communications, surge protector and remote temperature sensor (RTS). The
FLEXpower Radian is also equipped with battery, PV array breakers, GFDI, AFCI and input-output-bypass. See individual product datasheets or product guide for full specifications.
**Overcurrent protective device.
07/2020