Mate Specifications

44
FX STATUS Batt(ery) Screens
STATUS/FX/MODE-------------P00
battery 13.6 vdc
actual
DOWN STATUS PORT
STATUS/FX/METER-------------P00
absorb 14.4 vdc
setpoint
DOWN UP TOP PORT
STATUS/FX/MODE-------------P00
battery 13.6 vdc
temp compensated
DOWN UP TOP PORT
STATUS/FX/BATT---------------P00
absorb 00.0 hrs
time remaining
DOWN UP TOP PORT
STATUS/FX/BATT---------------P00
oat 24.0 hrs
time remaining
DOWN UP TOP PORT
STATUS/FX/BATT---------------P00
oat 13.6 vdc
setpoint
DOWN UP TOP PORT
BATT(ERY) Screens
• battery actual:batteryvoltageasmeasuredbytheFX
• battery temp compensated:theRemoteTemperatureSensor(RTS)mustbeconnectedtothisvaluetobe
measured
• absorb set point: charger set point for absorb recharging cycle
• absorb time remaining: time remaining in absorb recharging cycle
• oat set point: battery set point for oat recharging cycle
• reoat set point: at this battery voltage, the charger restarts the oat recharging cycle
• equalize set point:chargersetpointforequalizerechargingcycle
• equalize time remaining:timeremaininginequalizerechargingcycle
• batt temp:thisvalue,whichreectsthebatterytemperature,isusedbythechargerwhenanRTSisconnected
totheFX
eBATTMODEvaluescannotbechangedintheSTATUSscreens.
STATUS/FX/BATT---------------P00
reoat 12.5 vdc
setpoint
DOWN UP TOP PORT
STATUS/FX/BATT---------------P00
equalize 00.0 hrs
time remaining
DOWN UP TOP PORT
STATUS/FX/BATT---------------P00
equalize 14.4 vdc
setpoint
DOWN UP TOP PORT
STATUS/FX/BATT---------------P00
batt temp. 255
(not in degree C/F)
DOWN UP TOP PORT
STATUS/FX/PAGE1-------------------
choose category:
MODES METER BATT PG2
STATUS/FX/BATT---------------------
end of battery menu
UP TOP STATUS
Pressing the <PG2> so key
bringsupmoreSTATUS
categories.