- Outback Power Maximum Power Point Tracking Charge Controller Model MX60 PV MPPT Installation, Programming and User's Manual
17
OutBack Power Systems Inc.
Battery Voltage Screen
Press the “” soft key to select a battery voltage. The
MX60’s default values are based on a 12 VDC system.
Selecting a higher voltage system will change all the
default values (e.g., the values will double with a 24
VDC system, triple with a 36 VDC system, etc.). “^^”
indicates the chosen voltage. The MX60 will automat-
ically accept the selected battery voltage if left unat-
tended for 5 minutes in this screen. After choosing
the voltage, press the <ENTER> soft key to proceed.
Veri cation Screen
Press the <YES> soft key to proceed if the selected
battery voltage is correct. If incorrect, press <NO> to
re-enter the correct voltage.
Power-Up Screen
The MX60 brie y returns to the Power-Up screen and
then automatically opens the STATUS screen which
displays information regarding the recharging status.
Con rm the battery voltage displayed in the upper
right corner is correct.
BATTERY VOLTAGE
12 24 36 48 60
^^
EXIT ENTER
Are you sure?
12 24 36 48 60
^^
NO Yes
OutBack 12V
Power
Systems
MX60
Note: Repeating the Powering Up sequence resets
the MX Charge Controller to its factory default
settings.