- Outback Power Maximum Power Point Tracking Charge Controller Model MX60 PV MPPT Installation, Programming and User's Manual

79
OutBack Power Systems Inc.
STANDARD vs. AUSTRALIAN DEFAULT SETTINGS
The Australian version MX60 has a few default settings that di er from the Standard version default
settings. However, there are no di erences in performance and e ciency between the two ver-
sions. The Standard and Australian version can be identi ed as follows:
Standard version Australian version
Below are a few default setting di erences between the Standard and Australian version.
Settings Standard Australian
Charger Amps Absorb Float Amps Absorb Float
12 V 60 14.4 V 13.6 V 60 14.4 V 13.8 V
24 V 60 28.8 V 27.2 V 60 8.8 V 27.6 V
36 V 60 43.2 V 40.8 V 60 43.2 V 41.4 V
48 V 60 57.6 V 54.4 V 60 57.6 V 55.2 V
60 V 60 72.0 V 68.0 V 60 72.0 V 69.0 V
Equalize Equalize Volts Equalize Volts
12 V 14.4 14.7
24 V 28.8 29.4
36 V 43.2 44.1
48 V 57.6 58.8
60 V 72.0 73.5
Equalize Time 01 Hours 03 Hours
OutBack 12V
Power
Systems
MX60
OutBack 12V
Power
Systems
MX60-AU