- Outback Power Systems, Inc. Battery Charger User Manual

39
Setting LMIT Upper and Lower Set Points
In the DISCONNECT VOLTS screen, press the < -> or <+ >
soft key to adjust the battery voltage range limits. This
should be the lowest Absorb voltage when the battery
temperature is highest. When the desired low voltage is
reached, simultaneously press and hold the < - > and < +
> soft keys until Lower Limit displays on the screen. When
Lower Limit is displayed, the desired compensated volt-
age has been stored, and the < - > and < + > soft keys
can be released (pressing the <BACK> soft key will return
to the previous screen).
Press the <ReCon> soft key to adjust the upper battery
compensated voltage.
Press the < - > or < + > soft key to adjust the voltage.
When  nished, simultaneously press and hold the
< - > and < + > soft keys until Upper Limit is displayed.
This should be the highest Absorb voltage when the
battery temperature is coolest.
DISCONNECT VOLTS
<13.6
BACK - + ReCon
DISCONNECT VOLTS
<13.2
Lower Limit
BACK - + ReCon
RE-CONNECT VOLTS
>14.8
BACK - + DisV