OutBack Power SkyBox Quick Start Guide

Quick Start Guide
IMPORTANT:
Not intended for use with
life support equipment.
Contact Information
Mailing 1628 – West Williams Drive
Address: Phoenix, AZ 85027 USA
Web Site: www.outbackpower.com
NOTE: Additional information on
this product is available at
www.outbackpower.com. For
screen navigation, operation, and
troubleshooting, see the SkyBox
Overview Guide. For programming
and applications, see the SkyBox
Programming Guide.
Date and Revision
May 2020, Revision B
Listings:
o UL1778 5
th
Edition, 6/13/2016
o UL1741 2
nd
Edition, 1/28/2010 with supplement SA
o CSA22.2, No. 107.1-01 Ed:3 (R2006)
Certifications:
o HECO Rule 14 SRD
o California Rule 21 SRD
o IEEE 1547-2003
o IEEE 1547.1-2005
System Grounding and Bonding:
In this product, the PV, AC, and battery circuits are
isolated from the enclosure. This product has been
evaluated, listed and identified by UL to meet the
requirements of 690.41 and 250.4(A) of the NEC.
o The PV system ground reference and protection
is provided internal to the SkyBox, in accordance
with NFPA 70 690.41(A)(6).
o The AC connections are not bonded to ground.
The usual location for a neutral-ground bond is
at the main AC service panel. Make sure to
establish a neutral-ground bond when installing
in an off-grid application.
o The battery connection is not bonded to ground.
Make sure to establish a negative-ground bond for
each battery system. An 8½” AWG #4 green wire is
included with the hardware kit for this purpose.
Equipment grounding is required by Section 250 of the
National Electric Code (ANSI/NFPA 70) and Canadian
Electrical Code (C22.1).
Overcurrent Protection
o The battery disconnect device in the BOS does not
provide overcurrent protection. The installer must
provide protection for the battery circuit according to
the following parameters.
 Maximum 175 Adc
 Minimum 10 kA AIC
o AC overcurrent protection is provided in the BOS.
Electrical Specifications
o Maximum continuous output: 5000 VA @ 45°C
o Nominal input and output voltage: 120/240 Vac
o Nominal frequency: 60 Hz
o Maximum continuous output current: 24 Aac
o Maximum grid input current: 48 Aac
o Maximum generator input current: 48 Aac
o Maximum PV source voltage: 600 Vdc
o Operating PV source voltage range: 200 to 600 Vdc
o Maximum PV input current: 20 Adc
o Maximum PV short-circuit current: 32 Adc
o MPPT range: 250 to 600 Vdc
o A
UX output: 0.6 A @ 12 Vdc
o A
UX relay: 10 A @ 240 Vac, 5 A @ 30 Vdc
o Nominal battery voltage: 48 Vdc
o Maximum battery input current: 140 Adc
o Battery input voltage range: 42 to 60 Vdc
o Charging output voltage range: 42 to 60 Vdc
o Maximum battery charging current: 100 Adc
Supported Batteries
o Lead-acid
o Various lithium-ion models
Environmental Ratings:
o Environmental Category: Type 3R
o Maximum Altitude Rating: 10,000 feet
o Maximum Ambient Temperature: 60°C
Dimensions:
o Height 47.2" (119.9 cm)
o Width 21.0" (53.3 cm)
o Depth 9.4" (23.9 cm)
Weights:
o SkyBox: 87.7 lb (39.8 kg)
o BOS: 23.6 lb (10.7 kg)
o Mounting Bracket: 4.6 lb (2.1 kg)
Mounting Bracket
Ensure the mounting surface is strong enough to handle
three times the unit weight. (See the Specifications section.)
Add plywood or other material as necessary to strengthen the surface.
A Locate this horizontal slat at about eye level for easier display viewing.
B Do not place the top of the mounting bracket more than 6' (183 cm) above
the floor. This ensures that the SkyBox can be easily lifted onto the bracket.
Mark the placement of the bracket according to A and B, keeping in mind the
dimensions in the second drawing. These dimensions (see above*) show the SkyBox
overlap (beyond the bracket) as well as the vertical measurements with respect to A.
They also add the required minimum clearances of 6" (15.2 cm) to SkyBox top and sides.
(This clearance includes the requirements for SkyBoxes in parallel. See Commissioning.)
IMPORTANT:
No lower clearance is shown. In outdoor installations a 36" minimum clearance above the
ground or floor is required. The lower vertical measurement becomes 60.6” (153.9 cm) from A.
True Hybrid Energy System
Place the bracket so
that rails C and D are
flush with the surface.
Conduit Knockouts
(Underside of BOS)
SkyBox
BOS
(Balance of
System)
Left Right
1½" ¾” ¾” ¾” ¾” ¾” ¾”
6.0"
(15.2 cm)
Hole
spacing
B
A
16"
(40.5 cm)
Hole spacing
WARNING: Burn Hazard
The heat sink (at the top rear of the product) may
reach temperatures greater than 70°C. Install this
product so that casual contact does not occur.
WARNING: Fire/Explosion Hazard
Do not place combustible or flammable materials
within 12 feet (3.7 m) of the equipment. This unit
employs mechanical relays and is not ignition-
protected. Fumes or spills from flammable materials
could be ignited by sparks.
WARNING: Personal Injury
Use safe lifting techniques and standard safety
equipment when working with this equipment.
IMPORTANT:
 This document is for use by qualified personnel familiar with photovoltaic
(PV) systems and maximum power point tracking (MPPT) technology as
well as basic inverter functionality. Users of this document should meet
all local and governmental code requirements for licensing and training
for the installation of electrical power systems with AC and DC voltage
up to 600 volts. This product is only serviceable by qualified personnel.
 Clearance and access requirements may vary by location. A 36” (91.4 cm)
clear space in front of the system for access is recommended. Consult
local electric code to confirm clearance and access requirements for the
specific location. If this product is installed or used in a manner other than
specified, the protection it provides may be impaired.
 Fuses are not to exceed maximum output rating.
 When installed outdoors, use only UL514B-compliant wet location or
rain-tight conduit hubs for entry into the enclosure.
 See Specifications for instructions on system grounding and bonding.
CAUTION:
To reduce the risk of fire, connect only to a circuit
provided with a 60 amperes maximum branch-circuit
protection in accordance with the National Electric Code,
ANSI/NFPA 70.
!
28.6"
(72.6 cm)
A
24.6"
(62.5 cm)
9.4"
(23.9 cm)
32" *
(81.3 cm)
C
D
This image does not
depict the SkyBox on
the bracket, but the air
envelope around the
whole installation
(including clearances).
Tools Needed:
o 13 mm socket (torque) wrench
o #2 Phillips (torque) driver
o Flat blade (torque) driver
o 6 mm Allen wrench
o Digital multimeter (DMM)
Included in Box:
o SkyBox literature
o Battery conductors
o Ground bond conductor
o SkyBox labels
o Remote temperature sensor
o Hardware kit
900-0195-01-00 REV B
©2018 OutBack Power. All Rights Reserved.
Specifications

Summary of content (4 pages)