Outback FM60 User Manual

Operation
900-0009-01-00 Rev D 27
Initial Operation
Figure 15 Initial Operation
Changing the Settings on the FLEXmax
Accessing the Main Menu
The main menu allows the user to adjust and calibrate the FLEXmax for maximum performance.
Figure 16 Accessing the Main Menu
In 113.6V 0.0 A
Out 12.5V 0.0 A
0.000 kW 0.0 kWH
AUX: OFF Sleeping
Status Screen
From the status screen, press SK1
to open the main menu screen.
To return to the status screen from
the main menu, press <EXIT>
(also SK1).
Charger Aux Light
EQ Misc Advanced
Logging Stats
EXIT GO
Main Menu
In 113.6V 0.0 A
Out 12.5V 0.0 A
0.000 kW 0.0 kWH
AUX: OFF Sleeping
Status Screen
Turn the PV input circuit breaker ON. The FLEXmax automatically detects
the PV input voltage.
The FLEXmax enters Wakeup, transitions to Tracking, and prepares to
charge the batteries by tracking the maximum power point of the PV array.
During the initial tracking, the input PV source is gradually loaded from the
open-circuit voltage (V
oc
) to ½ of the V
oc
. Within this range, the FLEXmax
seeks the maximum power point.
When the FLEXmax goes into Re-Cal, Auto Restart, or Wakeup, modes,
among other conditions, it performs an initial tracking.
In 000.0V 0.0 A
Out 12.5V 0.0 A
0.000 kW 0.0 kWH
AUX: OFF Sleeping
Status Screen
If PV voltage registers 000V when the PV circuit breaker
is ON, check the polarity of the PV connections.