Outback FM60 User Manual

MATE3-Class Screens
900-0009-01-00 Rev D 63
DataLog Screen
The <DataLog> soft key shows accumulated daily amp-hour and watt-hour statistics, as well
as maximum current, wattage, and maximum and minimum voltage figures. These maintain a
continuous daily log, up to 128 days, which can be recalled. One day can be displayed at a
time. See page 58 for more information.
Figure 56 DataLog Screen
Soft Keys:
<+Day> advances the display forward by
a single day. If the display reads “Today”,
it does nothing.
<–Day> advances the display backward
by a single day and will display the
selected date.
<Back> returns to the previous screen.
<Port> cycles through each device
connected to the network.
Current Date
Screen Items:
The upper left corner shows the date of the
selected Datalog screen. (The current Datalog
screen reads "Today.") To the right, this line
also displays the kilowatt-hours and amp-hours
accumulated that day.
Max Output displays the maximum current and
wattage recorded that day.
A
bsorb The amount of time the Absorbing timer
ran that day.
Float The amount of time the Float timer ran
that day.
High VOC
displays the highest open-circuit
voltage (V
OC
) recorded that day.
Min Batt displays the lowest battery voltage
recorded that day.
Max Batt
displays the highest battery voltage
recorded that day.