Outback FM60 User Manual

MATE3-Class Screens
70 900-0009-01-00 Rev D
Calibrate
The Calibrate menu allows adjustment of the charge controller’s battery voltmeter. If a
particular controller’s readings do not match those of another device, or a hand-held meter, the
calibration feature may improve consistency.
Figure 76 Calibrate
NOTE: Calibration does not change the actual voltage of the charge controller, only the
reading of that voltage.
Also, measurements in places other than the charge controller’s terminals may differ regardless
of calibration. For example, it is possible to get a different reading at the charge controller’s DC
terminals than on the batteries. Connection problems, corrosion, and the effects of induction
and resistance may all result in voltage differences. If this occurs, note that this is an issue with
the system, not the charge controller. Calibration cannot correct for it.
Reset Charge Controller to Factory Defaults
This menu allows the user to erase all settings from the selected charge controller and start
over with the values programmed at the factory. These values are listed on page 96.
Figure 77 Restoring the Charge Controller to Factory Default Settings
To access the Reset to Factory Defaults menu:
1. Access the main menu as shown in Figure 16.
2. Select the Settings menu. (This option may be
highlighted by default.)
3. Select Charge Controller in the device Settings menu.
4. Select the Reset to Factory Defaults menu.
5. Use the soft keys to select No or Yes.
If <No> is selected, the screen returns to the
Charge Controller menu. No changes will be
made to any settings.
If <Yes> is selected, the inverter’s settings will
immediately change to the original factory values.
The screen will display the message Charge
Controller Restored to Factory Defaults
.
A <Continue> soft key will appear. Pressing this
key will return the screen to the Charge Controller
menu.
6. After resetting the charge controller to factory default
parameters:
press the <Continue> soft key or the Up
navigation key to return to the Charge Controller
menu, or
press the Top navigation key to return to the
Settings menu.
Press <Continue> to return to
the Charge Controller Menu.
Calibration Offset
Set Points:
o Battery Voltage – Calibrates the Vdc measurement
made at the controller’s battery terminals.