ICSPLUS Quick Start Guide

Specifications
900-0183-01-00 REV A
©2016 OutBack Power Technologies. All Rights Reserved.
Features:
 First end-to-end solution listed to UL1741 with PV rapid shutdown systems (PVRSS)
 Arc fault circuit interrupter (AFCI) listed to UL1699B with local and remote indication
 Type 3R enclosures rated for indoor or outdoor installation
 Flexible design — install the combiner box vertically or horizontally and mount to racking or under an array
 Interoperability with compatible third-party PV rapid shutdown devices (PVRSE with dry contact)
Components Included:
 ICS Plus Combiner Box
o FWPV6-FH600-SDA ( )
 Rapid Shutdown
Initiator Box
o RSI ( )
 Circuit Breaker
Control Box
o BKR-CTRL-DC ( )
 Relay-Trip Breaker (RTB) Device
o PNL-75-DC-RT ( )
o PNL-75D-DC-RT ( )
o PNL-75Q-DC-RT ( )
Listings
 UL1741
o including PVRSS
 UL1699/UL1699B
 CSA C22.2
o including PVRSS
Compliance
 FCC Part 15, Class B
NOTES:
 The DC input and output circuits
are isolated from the enclosure.
 The photovoltaic system grounding
shall be installed according to the
requirements of Sections 690.41
through 690.47 of the National
Electric Code (ANSI/NFPA 70).
The installer is responsible for all
system grounding.
 Use only UL514B-compliant wet
location or rain-tight conduit hubs
for entry into the enclosure.
Specifications
Integrated Combiner Solution Plus
Quick Start Guide
Dimensions
Adjustable
mounting feet
Lockable PV
disconnect
Lockable latch
Arc fault
test button
AFCI
annunciator
LED
indicators
Lockable
rapid shutdown
switch
19.5" (49.5 cm)
13.75"
(34.9 cm)
4.5"
(11.4 cm)
15.5"
(39.4 cm)
11.3"
(28.7 cm)
12.0"
(30.5 cm)
14.75"
(37.5 cm)
7.3” (18.5 cm)
6.6” (17.8 cm)
5.0” (12.7 cm)
14.1"
(35.8 cm)
1
2
3
4
5
6
Accessories Available:
 Box of (10) 15A Fuses
o FUSE-15-600VDC
 Box of (10) 20A Fuses
o FUSE-20-600VDC
Packages Available:
NOTE: All packages include (1) RSI, (1) BKR-CTRL-DC, (1) RTB device, and (1) or more FWPV6-FH600-SDA combiner
boxes. All packages are equipped with rapid shutdown, external disconnect, and PV AFCI functions.
 ICSPLUS-1: Compatible with up to 6 strings of PV (one charge controller); includes (1) FWPV6-FH600-SDA
 ICSPLUS-2: Compatible with up to 12 strings of PV (two charge controllers); includes (2) FWPV6-FH600-SDA
 ICSPLUS-4: Compatible with up to 24 strings of PV (four charge controllers); includes (4) FWPV6-FH600-SDA
1
2
3 4 5 6
Securing
Screw
5.75" (14.6 cm)
with feet
fully extended
4.4"
(11.2 cm)
2.0"
(5.1 cm)
3.25"
(8.3 cm)
0.75”
(1.9 cm)
5.25"
(13.3 cm)
3.75” (9.5 cm)
PV DISCONNECT
AFCI SELF TEST
AFCI ANNUNCIATOR
2"
½”
and
¾”
½”
All ½”
 30A, 1000 Vdc Fuse Holder
o FH-30-1000VDC-DIN
 PV Rapid Shutdown Label
o LBL-PVRSS
Combiner
600 Vdc
96 Adc
24 Vdc ± 3%
(6) 600 Vdc
DIN rail fuse
holders
0.10 Adc
UL Type 3R
–25 to 60°C
Arc Fault
2", ½”, ¾”
RSI
24 Vdc ± 3%
N/A
24 Vdc ± 3%
N/A
0.06 Adc
UL Type 3R
–25 to 60°C
SOLAR ON
SOLAR OFF
AFCI
½”
Device
Voltage
Total Current
DC Input
Overcurrent
Protection
Power Draw
Enclosure Rating
Ambient Temp.
LED indicators
Knockouts
BKR-CTRL-DC
N/A
N/A
24, 32, 36, 48 Vdc
(battery nominal)
3AG Cartridge,
3A slow-blow,
10kA@125VDC
0.05 Adc
UL Type 1 with
connector
enclosure
–25 to 50°C
N/A
N/A
RTB
300 Vdc/pole
75 Adc/pole
From
BKR-CTRL-DC
N/A
N/A
UL Open Type
–25 to 50°C
N/A
N/A
Up to 6 PV
input strings
per combiner
Controls up to
6 combiner
boxes and 2
relay-trip
breakers
Compatibility
Powers up to
6 combiner boxes
and 2 relay-trip
breakers
Up to 4 poles
1 pole: PNL-75-DC-RT
2 poles: PNL-75D-DC-RT
4 poles: PNL-75Q-DC-RT