With burner sitting on top of enclosure, connect
control switch to DSI system. The connector is
keyed and will only connect one way. See Image
6.3. It may be necessary to prop up burner in one
or more locations.
With burner in same position as in Step 3, connect
power adaptor to DSI system. The connections will
be labelled 3.3 VDC + and 3.3 VDC – on both the
DSI system and power adaptor. If they are not
connected properly, the unit will not operate.
See Image 6.4.
Using adjustable wrenches, tighten all connections
shown in Image 6.5. This step serves as a nal
safety measure as all ttings come tightened from
the factory.
Carefully place burner assembly into enclosure
DO NOT USE IGNITION ELECTRODES AS A
HANDLE. Evenly spread included glass media over
burner surface. Glass media MUST be
present inside ignition wind guard. Place 38-42
OGC standard glass beads within the wind guard.
Media SHOULD NOT contact the ignition
electrodes. See Image 6.6.
If using media other than the included standard
glass beads, one layer of media within the ignition
wind guard is sucient keeping in mind that
media CANNOT be in contact with ignition
electrodes.
3.
4.
5.
6.
(Img. 6.3)
(Img. 6.4)
(Img. 6.5)
(Img. 6.6)
OUTLET CONNECTION
FROM DSI TO BURNER
CONNECTION FROM
FLEX-LINE TO ORIFICE
INLET CONNECTION
FROM REGULATOR HOSE
TO DSI SYSTEM
BURNER SURFACE
IGNITION WIND GUARD
IGNITION ELECTRODES