User Manual

3
2.2 Powering Up and Powering Down:
Before you power up make sure you read all the safety warnings (page 33), it won’t
take much time.
Use only the power supply that comes with the Creamsource Micro. Its input
is auto-ranging from 100-240V AC, 50/60Hz for use world-wide.
Attach power supply to main power source. With the power supply turned
OFF, connect the power cable to the light head. This procedure will extend
the life of the connectors.
The Creamsource Micro remembers its last brightness setting, if the light was
turned on or off and the last MODE it was used in.
Up to 10m (32ft) of extension cable can be run between the power supply and
the head.
The power should be switched off before unplugging the cable. There are no
other special procedures for powering down - it can be done at any time without
harm to the unit.
If the external flexible cable of
this luminaire is damaged, it
must be replaced by an original
cable from the manufacturer
or service agent.
2.3 Batteries
The Creamsource Micro can be run on DC battery power directly with no
additional hardware required. Any voltage source between 10V and 32V which is
capable of 80 watts draw can be used. The LED array will turn off if the voltage falls
below 10V, so it is advisable to use 14.4V or higher for best performance.