The intent of this document is to provide guidance on the installation of Owens Corning
®
FOAMULAR
®
Insulation in residential
and light frame commercial construction. This document, the reference documents cited herein and any/all information found
on product packaging, literature, and videos collectively constitute the “manufacturer’s installation instructions” referenced in
the ICC family of model codes – specifically the Intl. Energy Conservation Code (IECC), Intl. Residential Code (IRC) and Intl.
Building Code (IBC).
General Guidelines
Optimum performance of Owens Corning
®
FOAMULAR
®
Insulation products is dependent on 1) selection of the correct
product for the assembly or application into/on which it is to be placed and 2) following these installation instructions. General
guidelines which apply to both selection and installation include:
The framed assembly or masonry surface onto which the Insulation is to be applied must be flat. FOAMULAR
®
Insulation
is a rigid product and not intended for uneven surfaces. Any deformation of the application surface can result in a
weakening of the attachment points and/or cracking of the insulation.
There should be no voids or gaps in the insulation itself, around any objects that penetrate the insulation or at the
interface of the insulation and framing members.
• FOAMULAR
®
Insulation is not structural. Structural sheathing or code compliant bracing must be used when applying to
wood or metal framing.
Materials
FOAMULAR
®
Installation Guidelines
FOAMULAR
®
Product and Accessories Guide
Thickness requirements vary by application and energy codes
thermal resistance value: R-5 per inch of thickness
Minimum compressive strength: F-150 and INSULPINK
®
Foam Insulation Board= 15 psi
Minimum compressive strength: F-250 and Insul-Drain
®
Drainage Board= 25 psi
F-150 F-250 Insul-Drain
®
INSULPINK
®
ACCESSORIES
Above grade
Selection of F-150 versus F-250 product
is dependent on minimum compressive
strength requirements, based on chosen
cladding type. Consult cladding manufacturer
for recommendation.
• ProPink ComfortSeal
Sill Gasket
• ProPink ComfortSeal
Framing Gasket
• FlashSealR
®
Flashing Tape
• 1" diameter cap nails at a length sufcient to
penetrate the framing a minimum of ¾"
Exterior below grade
Insul-Drain
®
Drainage Board incorporates
precision-cut channels to drain water from
vertical foundation walls and is recommended
for use in areas where water drainage is a
concern.
• Adhesive compatible with polystyrene or foamed
plastics as noted by its manufacturer
• LOCTITE
®
PL
®
300 VOC Foamboard Adhesive
• Other equivalent alternative
Interior above/below grade masonry wall
FOAMULAR
®
applied in conditioned space
must be covered by a 15-minute thermal
barrier, such as gypsum board. INSULPINK
®
Foam Insulation Board is 1½" thick,
provides a thermal resistance of R-7.5, and
incorporates pre-cut slotted edges ready to
accommodate 1" x 3" wood furring strips for
easy installation of finished covering.
F-150
• Adhesive compatible with polystyrene or foamed
plastics as noted by its manufacturer
• LOCTITE
®
PL
®
300 VOC Foamboard Adhesive
• Liquid Nails
®
Projects and Foamboard Adhesive
• Other equivalent alternative
INSULPINK
®
Foam Insulation Board
• 2½" minimum length concrete fasteners
• 1" x 3" wood furring strips
Below concrete slab
Consult a Structural Engineer for
compressive strength requirements for
your specific application. 40psi - 100psi
compressive strength material is available for
high load applications.
• Polyethylene vapor barrier