Technical Specifications

Limited Warranty
FOAMULAR
®
XPS insulation limited lifetime warranty maintains 90% of its R-value for
the lifetime of the building and covers all ASTM C578 properties. See actual warranty
for complete details, limitations and requirements at www.owenscorning.com.
Environmental and Sustainability
Owens Corning is a worldwide leader in building material systems, insulation and
composite solutions, delivering a broad range of high-quality products and services.
Owens Corning is committed to driving sustainability by delivering solutions, transforming
markets and enhancing lives. More information can be found at www.owenscorning.com.
Disclaimer of Liability
Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient’s sole
risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not
responsible or liable for the accuracy or reliability of data associated with particular uses of any product described herein. SCS
Global Services provides independent verication of recycled content in building materials and veries recycled content claims
made by manufacturers. For more information, visit www.SCSglobalservices.com.
LEED
®
is a registered trademark of the U.S. Green Building Council.
Notes
For additional information, refer to the Safe Use Instruction Sheet (SUIS) found in the SDS Database via
http://sds.owenscorning.com.
Available lengths and edge congurations vary by thickness. Other sizes may be available upon request. Consult your local
Owens Corning representative for availability.
Certications and Sustainable Features
Certied by SCS Global Services to contain a minimum of 20%
recycled content pre-consumer
GREENGUARD Certied products are certied to GREENGUARD
standards for low chemical emissions into indoor air during
product usage. For more information, visit ul.com/gg
Environmental Product Declaration (EPD) has been certied
by UL Environment
Qualied as an ENERGY STAR
®
product, under the U.S.
Environmental Protection Agency and the U.S. Department
of Energy
Utilizing FOAMULAR
®
XPS insulation can help builders achieve
green building certications including the U.S. Green Building
Council’s Leadership in Energy and Environmental Design
(LEED
®
) certication
Product and Packaging Data
MATERIAL
Extruded polystyrene closed-cell foam, ASTM C578 Type IV, 25
psi minimum
PACKAGING
Shipped in poly-wrapped units with individually wrapped or
banded bundles.
THICKNESS
(IN)
PRODUCT
DIMENSIONS
THICKNESS (IN)
X WIDTH (IN) X
LENGTH (IN)
PALLET (UNIT)
DIMENSIONS
(TYPICAL) WIDTH (FT)
X LENGTH (FT) X
HEIGHT (FT)
SQUARE
FEET
PER
PALLET
BOARD
FEET
PER
PALLET
BUNDLES
PER
PALLET
PIECES
PER
BUNDLE
PIECES
PER
PALLET
EDGES
¾ ¾ x 24 x 96 4 x 8 x 8 4,096 3,072 8 32 256 Square
Edge,
Scored
Square
Edge,
Tongue
&
Groove
¾ x 24 x 96 (half unit) 4 x 8 x 4 2,048 1,536 4 32 128
¾ x 48 x 96 4 x 8 x 8 4,096 3,072 8 16 128
¾ x 48 x 96 (half unit) 4 x 8 x 4 2,048 1,536 4 16 64
¾ x 48 x 108 4 x 9 x 8 4,608 3,456 8 16 128
¾ x 48 x 120 4 x 10 x 8 5,120 3,840 8 16 128
1 1 x 24 x 96 4 x 8 x 8 3,072 3,072 8 24 192
1 x 24 x 96 4 x 8 x 8 3,072 3,072 8 24 192
1 x48 x 96 4 x 8 x 8 3,072 3,072 8 12 96
1 x 48 x 96 (Half unit) 4 x 8 x 8 1,536 1,536 4 12 48
1 x48 x 108 4 x 9 x 8 3,456 3,456 8 12 96
1.5 x 24 x 96 4 x 8 x 8 2,048 3,072 8 16 128
1.5 x 48 x 96 4 x 8 x 8 2,048 3,072 8 8 64
2 2 x 24 x 96 4 x 8 x 8 1,536 3,072 8 12 96
2 x 24 x 96 (half unit) 4 x 8 x 4 768 1,536 4 12 48
2 x 24 x 108 4 x 9 x 8 1,728 3,456 8 12 96
2 x 48 x 96 4 x 8 x 8 1,536 3,072 8 6 48
2.5 x 24 x 96 4 x 8 x 8 1,152 2,830 8 9 72
2.5 x 48 x 96 4 x 8 x 8 1,152 2,830 4 9 36
3 3 x 24 x 96 4 x 8 x 8 1,024 3,072 8 8 64
3 x 48 x 96 4 x 8 x 8 1,024 3,072 8 4 32
4 4 x 24 x 96 4 x 8 x 8 768 3,072 8 6 48
4 x 48 x 96 4 x 8 x 8 768 3,072 8 3 24
Pub. No. 43522-M. Printed in U.S.A. December 2019. THE PINK
PANTHER™ & © 1964–2019 Metro-Goldwyn-Mayer Studios Inc. All
Rights Reserved. The color PINK is a registered trademark of Owens
Corning. © 2019 Owens Corning. All Rights Reserved.
OWENS CORNING FOAM INSULATION, LLC
ONE OWENS CORNING PARKWAY TOLEDO, OHIO 43659
1-800-GET-PINK
®
www.owenscorning.com
Technical Information
FOAMULAR
®
250 XPS insulation is a non-
structural material and must be installed
on framing which is independently braced
and structurally adequate to meet required
construction and service loading conditions.
FOAMULAR
®
250 XPS insulation can be
exposed to the exterior during normal
construction cycles. During that time
some fading of color may begin due to UV
exposure, and, if exposed for extended
periods of time, some degradation or
dusting” of the polystyrene surface may
begin. It is best if the product is covered
within 60 days to minimize degradation.
Once covered, the deterioration stops, and
damage is limited to the thin top surface
layers of cells. Cells below are generally
unharmed and still useful insulation.
FOAMULAR
®
250 XPS insulation has a
maximum service temperature of 165°F.
Install only as much FOAMULAR
®
XPS
insulation as can be covered in the same
day. For horizontal applications, always
turn the print side down so the black print
does not show to the sun which may at
times act as a solar collector, raising the
temperature of the foam under the print to
an unacceptable level.
Do not cover FOAMULAR
®
XPS insulation
either stored (factory wrapped or
unwrapped), or partially installed, with dark
colored (non-white), or clear (non-opaque)
coverings and leave it exposed to the sun.
Examples of such coverings include but
are not limited to lter fabrics, membranes,
temporary tarps, clear polyethylene, etc.
If improperly covered, and exposed to
the right combination of sun, time and
temperature, FOAMULAR
®
XPS insulation
deformation damage may occur rapidly. See
Owens Corning publication “Heat Build Up
Due to Solar Exposure” (Pub. No. 10015704)
for more information.
This product is combustible. A protective
barrier or thermal barrier is required to
separate this product from interior living
or conditioned spaces as specied in the
appropriate building code.
All construction should be evaluated for
the necessity to provide vapor retarders.
See current ASHRAE Handbook of
Fundamentals.