Full Product Manual

Features
Applications
Under slabs
Perimeter/Foundation walls
Cavity walls
Precast walls
Weather-resistant barrier (when joints are sealed)
Standards, Codes Compliance
Meets ASTM C578 Type IV
UL Classication Certicate U-197
Code Evaluation Report UL ER8811-01
ASTM E119 Fire Resistance Rated Wall Assemblies
3
Meets California Quality Standards; HUD UM #71a
3 Visit www.owenscorning.com for more details
Product Data Sheet | FOAMULAR
®
& FOAMULAR
®
NGX™ 250 XPS Insulation | December 2020
SUPERIOR
MOISTURE
RESISTANCE
EASY TO CUT,
FORM & FIT
DURABLE
Physical Properties
4
PROPERTY TEST METHOD
5
VALUE
Thermal Resistance,
6
R-Value, hr•ft
2
•°F/Btu
(RSI, °C•m
2
/W)
 @ 75°F (24°C) mean temperature
ASTM C518
5.0 (0.88)
 @ 40°F (4.4°C) mean temperature 5.4 (0.95)
 @ 25°F (-3.9°C) mean temperature 5.6 (0.99)
Long-Term Thermal Resistance,
LTTR-Value
7
, minimum hr•ft
2
°F/Btu (RSI, °C•m
2
/W)
 @ 75°F (24°C) mean temperature
CAN/ULC
S770-03
5.0 (0.88)
Compressive Strength
7
, minimum psi (kPa) ASTM D1621 25 (172)
Flexural Strength
8
, minimum psi (kPa) ASTM C203 50 (345)
Water Absorption
9
, maximum % by volume ASTM C272 0.3
Water Vapor Permeance
10
, maximum perm
(ng/Pa•s•m
2
)
ASTM E96 1.5 (86)
Dimensional Stability, maximum % linear change ASTM D2126 2.0
Flame Spread
11, 12
ASTM E84 10
Smoke Developed
11, 12
ASTM E84 175
Oxygen Index
11
, minimum % by volume ASTM D2863 24
Service Temperature, maximum °F (°C) - 165 (74)
Linear Coecient of Thermal Expansion, in/in/°F
(m/m/°C)
ASTM E228 3.5 x 10
-5
(6.3 x 10
-5
)
4 Properties shown are representative values for 1" thick material, unless otherwise specied.
5 Modied as required to meet ASTM C578.
6 R means the resistance to heat ow; the higher the value, the greater the insulation
power. This insulation must be installed properly to get the marked R-value. Follow the
manufacturer’s instructions carefully. If a manufacturer’s fact sheet is not provided with the
material shipment, request this and review it carefully. R-values vary depending on many
factors, including the mean temperature at which the test is conducted and the age of the
sample at the time of testing. The U.S. FTC requires the R-value of home insulation to be
measured at 75 degrees F mean temperature. R-value claims should always be compare at
the same mean temperature. Because rigid foam plastic insulation products are not all aged
in accordance with the same standards, it is useful to publish comparison R-value data. The
R-value for FOAMULAR
®
& FOAMULAR
®
NGX™ XPS Insulation is provided from testing at
mean temperatures of: -4°C (25oF), 4.4°C (40°F), and 24°C (75°F) and aging techniques of
180-day real time aged (as mandated by ASTM C578) and accelerated aging “Long-Term
Thermal Resistance” (LTTR) per CAN/ULC S770-03.
7 Values at yield or 10% deection, whichever occurs rst.
8 Value at yield or 5%, whichever occurs rst.
9 Data ranges from 0.00 to value shown due to the level of precision of the test method.
10 Water vapor permeance decreases as thickness increases.
11 These laboratory tests are not intended to describe the hazards presented by this material
under actual re conditions.
12 Data from Underwriters Laboratories Inc.
®
classied. See Classication Certicate U-197.
FOAMULAR
®
&
FOAMULAR
®
NGX
250
EXTRUDED POLYSTYRENE (XPS)
RIGID FOAM INSULATION
Owens Corning
®
FOAMULAR
®
& FOAMULAR
®
NGX™ 250 Extruded
Polystyrene (XPS) Insulation are closed-cell, moisture-resistant
rigid foam boards well suited to meet the needs of a wide variety of
building applications.
1
Both products are great for above-and below-
grade residential and commercial applications such as perimeter/
foundation, cavity wall, precast concrete, under slab, and other
applications.
FOAMULAR
®
NGX™ 250 contains the additional benet of being
manufactured with a blowing agent formulation that delivers a 90%
reduction to Global Warming Potential (100 year), including the
complete elimination of HFC 134a.
2
1 Not for use in at or low slope roong. For low slope roong applications, use FOAMULAR
®
& FOAMULAR
®
NGX™ THERMAPINK
®
or FOAMULAR
®
& FOAMULAR
®
NGX™ 400/600/1000
Extruded Polystyrene (XPS) Rigid Foam Insulation.
2 Compared to FOAMULAR
®
250 blowing agent formulation.

Summary of content (2 pages)