Product Specifications

Fiberglass-Based Asphalt Shingles & Accessories
2. A Dual Compound Formulation to meet performance needs of different layers: top coat
compound provides excellent granule adhesion (cap sheet), back coat compound provides
aggressive adhesion to the substrate.
3. Granule free adhesive selvedge on both the sides and end laps (cap sheet).
4. The DeckSeal System is designed for use on ¼:12 to 2:12 roof slopes.
5. The DeckSeal components include:
a) DeckSealSBS SA Cap Sheet - self-adhered granulated cap sheet
b) DeckSeal™ SBS SA Base/Ply Sheet - A self-adhered base/ply sheet
c) DeckSeal™ MA Nailbase - A nailable base sheet - where a nailable base sheet or self-
adhered base/play is used as a base layer for the granulated cap sheet for a minimum
recommended 2 ply system, and where a self-adhered base/ply can be used as a 2
nd
layer
in a 3-ply system.
6. Attractive colors that complement popular shingle offerings.
7. Roll Dimensions:
a) 32 ft. 10 in. by 39-3/8 in. Cap sheet
b) 65 ft. 8 in. by 39-3/8 in. Nailable base or self-adhered base
8. Standards/Qualifications: UL 790/ASTM E108 fire resistance
1
; FM 4474 wind uplift resistance
2
;
ASTM D6163 (base/ply sheet), ASTM D6164 (cap sheet); Florida Product Approval for use in
HVHZ and Non-HVHZ areas; and Miami-Dade Product Approval.
1
Class A, B, or C fire resistance based on system used and slope of roof. Consult the UL Online
Classification Directory for fire resistance classifications for specific systems.
2
Check local building codes for wind uplift requirements and DeckSeal literature for wind uplift resistance
information.
2.8 ROOF VENTILATION
**NOTE TO SPECIFIER** Delete attic ventilation products from the list below that are not required.
**NOTE TO SPECIFIER** Verify with the manufacturer regional product availability.
A. VentSure
®
RidgeCat
®
Rolled Ridge Vent.
1. Shingle-over, low profile ridge vent with nylon entangled-net structure allows the passage of hot
and/or moisture-laden air from attics, while prohibiting wind-driven rain.
2. Provides 15 sq in (9677 sq mm) NFVA per lineal foot.
3. Available in 20 ft (6.1 m) rolls in three different widths (regional availability):11 in (279 mm), 7 in
(178 mm), and 9 in (229 mm) widths.
4. Suitable on roofs with a pitch from 2:12 to 18:12.
5. Standards/Qualifications: Passes Wind-Driven Rain with 8.8 in (224 mm) of rain/hr at 110 mph
(177 km/h), ICC-ES AC132, UL ER21292-01, Florida Product Approval.
B. VentSure
®
Rigid Roll Ridge Vent with Weather PROtector
®
Moisture Barrier.
1. Shingle-over, low profile ridge vents with Weather PROtector
®
Moisture Barrier allows the
passage of hot and/or moisture-laden air from attics, while prohibiting snow infiltration.
2. Provides 12.5 sq in (8200 sq mm) NFVA per lineal foot.
3. Available in 20 ft (6.1 m) rolls in three different widths (regional availability): 7 in (178 mm), 9 in
(229 mm), and 11-1/4 in (286 mm).
4. Suitable on roofs with a pitch from 2:12 to 20:12.
5. Standards/Qualifications: ICC-ESR 2664, Passes Wind-Driven Rain with 8.8 in (224 mm) of
rain/hr at 110 mph (177 km/h), and Snow Infiltration at 35 mph (56 km/h) and 70 mph (112
km/h) Tests, UL ER21292-01, Florida Product Approval, and Miami-Dade County Product
Approval.
C. VentSure
®
4 ft (1.2 m) Strip Heat and Moisture Ridge Vent, 12 in width
1. Shingle-over, polypropylene ridge ventilator designed to work with eave/soffit intake ventilation
to maximize the flow of cool, fresh air through the roof and attic structure.