The intent of this document is to provide guidance on the installation of Owens Corning
®
FOAMULAR
®
Insulation in residential
and light frame commercial construction. This document, the reference documents cited herein and any/all information found
on product packaging, literature, and videos collectively constitute the “manufacturer’s installation instructions” referenced in
the ICC family of model codes – specifically the Intl. Energy Conservation Code (IECC), Intl. Residential Code (IRC) and Intl.
Building Code (IBC).
General Guidelines
Optimum performance of Owens Corning
®
FOAMULAR
®
Insulation products is dependent on 1) selection of the correct
product for the assembly or application into/on which it is to be placed and 2) following these installation instructions. General
guidelines which apply to both selection and installation include:
• The framed assembly or masonry surface onto which the Insulation is to be applied must be flat. FOAMULAR
®
Insulation
is a rigid product and not intended for uneven surfaces. Any deformation of the application surface can result in a
weakening of the attachment points and/or cracking of the insulation.
• There should be no voids or gaps in the insulation itself, around any objects that penetrate the insulation or at the
interface of the insulation and framing members.
• FOAMULAR
®
Insulation is not structural. Structural sheathing or code compliant bracing must be used when applying to
wood or metal framing.
Materials
FOAMULAR
®
Installation Guidelines
FOAMULAR
®
Product and Accessories Guide
Thickness requirements vary by application and energy codes
thermal resistance value: R-5 per inch of thickness
Minimum compressive strength: F-150 and INSULPINK
®
Foam Insulation Board= 15 psi
Minimum compressive strength: F-250 and Insul-Drain
®
Drainage Board= 25 psi
F-150 F-250 Insul-Drain
®
INSULPINK
®
ACCESSORIES
Above grade
Selection of F-150 versus F-250 product
is dependent on minimum compressive
strength requirements, based on chosen
cladding type. Consult cladding manufacturer
for recommendation.
✓ ✓
• ProPink ComfortSeal
™
Sill Gasket
• ProPink ComfortSeal
™
Framing Gasket
• FlashSealR
®
Flashing Tape
• 1" diameter cap nails at a length sufficient to
penetrate the framing a minimum of ¾"
Exterior below grade
Insul-Drain
®
Drainage Board incorporates
precision-cut channels to drain water from
vertical foundation walls and is recommended
for use in areas where water drainage is a
concern.
✓ ✓
• Adhesive compatible with polystyrene or foamed
plastics as noted by its manufacturer
• LOCTITE
®
PL
®
300 VOC Foamboard Adhesive
• Other equivalent alternative
Interior above/below grade masonry wall
FOAMULAR
®
applied in conditioned space
must be covered by a 15-minute thermal
barrier, such as gypsum board. INSULPINK
®
Foam Insulation Board is 1½" thick,
provides a thermal resistance of R-7.5, and
incorporates pre-cut slotted edges ready to
accommodate 1" x 3" wood furring strips for
easy installation of finished covering.
✓ ✓
F-150
• Adhesive compatible with polystyrene or foamed
plastics as noted by its manufacturer
• LOCTITE
®
PL
®
300 VOC Foamboard Adhesive
• Liquid Nails
®
Projects and Foamboard Adhesive
• Other equivalent alternative
INSULPINK
®
Foam Insulation Board
• 2½" minimum length concrete fasteners
• 1" x 3" wood furring strips
Below concrete slab
Consult a Structural Engineer for
compressive strength requirements for
your specific application. 40psi - 100psi
compressive strength material is available for
high load applications.
✓
• Polyethylene vapor barrier