Installation Guide
Product Data Sheet
raft-R-mate
®
Attic Rafter Vents with Optional Air Stop/Insulation Block
2. The vent should extend some
distance beyond the top of the
horizontal brous insulation.
3. Optional air stop/insulation
block. Bend down accordion
hinge to meet the top plate and
staple to the top plate exterior
face or top eave. Add additional
staples every 10"-12" into edge
anges. Staples must never
penetrate completely through
roof sheathing.
Installing Rafter Cavity
Insulation in Cathedral
Ceilings
1. Install raft-R-mate attic vent in
each rafter cavity beginning at
the sof t area, to assure the
vent remains open, continue
up the cavity to the ridge vent
or to a common air space.
2. Optional air stop/insulation
block–When installing, bend
down accordion hinge to meet
the top plate and staple to the
top plate exterior face or top
eave. Add additional staples every
10"-12" into edge anges. Staples
must never penetrate completely
through roof sheathing.
3. raft-R-mate attic vent should be
installed with an approximate
2" gap between the ends to
allow moisture to escape more
readily into the air channel.
Reduce gap to ½ " when using
blown-in loose ll insulation.
4. Install cavity batt insulation so
that the ends of the insulation
do not occur in the location
of the raft-R-mate attic vent
gap. This precaution minimizes
the potential of the insulation
expanding into the air channel
and restricting air ow.
Note to Builders and Consumers:
Building location, climate, use
and other factors will impact
construction of the ceiling
insulation and ventilation systems.
Always check with your local
building department for required
ventilation area in attics and rafter
cavities, requirements for vapor
retarders, and the acceptability
of raft-R-mate attic vent for the
planned application.
Technical Information
1-800-GET-PINK
™
For more information on the
Owens Corning family of home
building products, contact your
Owens Corning dealer or call:
1-800-GET-PINK
™
.
Caution
Combustible. Although
raft-R-mate attic vents meet
building code requirements of
< 75 ame spread and < 450
smoke developed, this product
will ignite if exposed to re of
suf cient heat and intensity.
Fresh Air Flow
raft-R-mate
Attic Vents
Soft Vent
Fibrous Insulation
Fresh Air Flow
OWENS CORNING FOAM INSULATION, LLC
ONE OWENS CORNING PARKWAY
TOLEDO, OHIO 43659
1-800-GET-PINK
™
ww w.owenscorning.com
Pub. No. 102899-E. Printed in U.S.A. November 2010. THE PINK
PANTHER™ & ©1964-2010 Metro-Goldwyn-Mayer Studios Inc.
All Rights Reserved. The color PINK is a registered trademark of
Owens Corning. ©2010 Owens Corning.