Dimensions Guide

PRODUCT DATA SHEET
EcoTouch
®
PINK
®
Fiberglas
Insulation
Description
Owens Corning
®
EcoTouch
®
PINK
®
Fiberglas
Insulation with
PureFiber
®
Technology is a preformed, fl exible blanket
insulation. It is produced in R-values from 11 to 49, with
thicknesses ranging from 3½ inches to 14 inches. It is available
unfaced, or faced with either a kraft or foil vapor retarder.
Features
Excellent thermal control
Effective acoustical control
Long term performance and will not settle nor slump
within wall cavities
With less dust than other fi berglass products, EcoTouch
®
PINK
®
Fiberglas
insulation has excellent stiffness and
recovery characteristics
1
Compression packaging from Owens Corning speeds job
site handling and installation
1. According to 2010 clinical trial conducted in Toronto, Canada by Ducker Worldwide on behalf
of Owens Corning Insulation Systems, LLC.
Applications
Wood-framed wall, fl oor and roof/ceiling cavity wall
assemblies
Metal-framed wall and fl oor cavity wall assemblies
Furring strips installed on the interior surface of basement
walls
Interior surfaces of basement and unvented crawl space
foundation walls
Standards, Codes Compliance
Manufactured in compliance with ASTM C 665
Federal Speci cation HH-I-521F has been canceled and
is replaced by ASTM C 665
Classifi ed non-combustible when tested in accordance
with ASTM E 136
Unfaced EcoTouch
®
PINK
®
Fiberglas
insulation is
acceptable for use in ICC building construction types I
through V; kraft and foil faced EcoTouch
®
PINK
®
Fiberglas
insulation are acceptable for use in ICC building
construction types III, IV and V
Certi ed to meet California Code of Regulations, Title
24, Chapter 12-13, Article 3, “Standards for Insulating
Material”
Design Considerations
For optimum insulation performance the building thermal
barrier (insulation) should be in continual alignment with
the building air barrier. In framed cavities, the product
thickness should match the depth of the framing members.
Follow the local, applicable building code(s) to determine
the need for and placement of a vapor retarder.
Do not install insulation on top, or within 3 inches of a
recessed light fi xture unless the fi xture is labeled as
“insulation contact” (IC) rated.
Kraft and standard foil facings will burn and cannot be left
exposed. Install facings in substantial contact with the
assembly fi nish material. Protect from open fl ame or other
heat source.
Installation
See Owens Corning publication “Installation Guide for
Light Density Insulation” (Pub. No. 10017858) for more
information.
Physical Properties
Property (unit) Test Value
Thermal Resistance ASTM C518 See “Availability” table
for R-values
Surface Burning Characteristics
2
(fl ame spread / smoke developed)
Unfaced
Kraft faced
Foil faced
ASTM E 84 / UL 723
25 / 50
NR / NR
75 / 150
Critical Radiant Flux (W/cm
2
)ASTM E970 >0.12
Water Vapor Permeance (perms)
Kraft faced
Foil faced
ASTM E96
1.0
0.5
Water Vapor Sorption
(by weight)
ASTM C1104 <5%
Odor Emission ASTM C1304 Pass
Corrosion Resistance ASTM C665, part 13.8 Pass
Fungi Resistance ASTM C1338 Pass
2. The surface burning characteristics of EcoTouch
®
Insulation were derived from products
tested in accordance with ASTM E84. This standard is used solely to measure and describe
properties of products in response to heat and fl ame under controlled laboratory conditions,
and should not be used to describe or approve the fi re hazard of materials under actual fi re
conditions. However, the results of these tests may be used as elements of a fi re risk assess-
ment that takes into account all of the factors pertinent to an assessment of the fi re hazard of
a particular end use. Values are reported to the nearest fi ve rating.

Summary of content (2 pages)