Digital Multimeter User Manual B35(T) D35(T) Note: "T" indicates true RMS (optional) WWW.OWON.
Mar.2015 edition V1.1 Copyright © Lilliput Company. All rights reserved. The Lilliput's products are under the protection of the patent rights, including ones which have already obtained the patent rights and those which are applying for. The information in this manual will replace all that in the materials published originally. The information in this manual was correct at the time of printing.
General Warranty Lilliput warrants that the product will be free from defects in materials and workmanship for a period of 1 year from the date of purchase of the product by the original purchaser from the Lilliput Company. This warranty only applies to the original purchaser and is not transferable to the third party, and does not apply to fuses, disposable batteries or to any product which has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling.
Table of Contents 1.Safety Information .................................................................................................... 1 Safety Considerations............................................................................................................... 1 Measurement Category ............................................................................................................ 3 Safety Terms and Symbols...............................................................................
Capturing Max. and Min. Values ............................................................................................17 Making Relative Measurements .............................................................................................17 Buzzer Feature........................................................................................................................ 18 6.Bluetooth Function – B35(T) only ............................................................................
1.Safety Information 1. Safety Information Safety Considerations Before any operations, please read the following safety precautions to avoid any possible bodily injury and prevent damage to this product or any other products connected. To avoid any contingent danger, use this product only as specified. Limit operation to the specified measurement category, voltage, or amperage ratings. Do not use the multimeter if it is damaged. Before you use the multimeter, inspect the case.
1.Safety Information When using the test leads, keep your fingers behind the finger guards on the test leads. Remove the test leads from the multimeter before you open the battery cover. To avoid false readings, which may lead to possible electric shock or personal injury, appears and flashes. replace the battery as soon as the low battery indicator Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance.
1.Safety Information Measurement Category The multimeter has a safety rating of 1000 V, CAT III. Measurement category definition Measurement CAT I applies to measurements performed on circuits not directly connected to the AC mains. Examples are measurements on circuits not derived from the AC mains and specially protected (internal) mains- derived circuits.
1.Safety Information Safety Terms and Symbols Safety Terms Terms in this Manual. The following terms may appear in this manual: Warning: Warning indicates the conditions or practices that could result in personal injury or death. Caution: Caution indicates the conditions or practices that could result in damage to this product or other property. Terms on the Product. The following terms may appear on this product: Danger: It indicates an injury or hazard may immediately happen.
2.General Characteristics 2.
3.Quick Start 3. Quick Start General Inspection After you get a new multimeter, make a check on the instrument according to the following steps: 1. Check whether there is any damage caused by transportation. If it is found that the packaging carton or the foamed plastic protection cushion has suffered serious damage, do not throw it away first till the complete device and its accessories succeed in the electrical and mechanical property tests. 2.
3.Quick Start (2) Lift the tilt stand and loosen the screws with a suitable Phillips screwdriver and remove the battery cover. (3) Observe the battery polarity indicated inside the battery compartment, Insert the batteries. (4) Place the battery cover back in its original position and tighten the screws. Caution: To avoid instruments being damage from battery leakage, always remove the batteries and store them separately if the multimeter is not going to be used for a long period.
3.Quick Start Selecting the Range Auto ranging is set as default when the meter is powered on, When auto ranging is enabled, press In manual range, each additional press of is displayed. to enter the manual range mode. sets the multimeter to the next higher range, unless it is already in the highest range, at which point the range switches to the lowest range. When manual range is enabled, press for more than 2 seconds to enter the auto ranging mode.
3.Quick Start No.
3.Quick Start Page 15 Select frequency/duty cycle Capturing Max. and Min.
3.Quick Start Continuity test selected Page 14 Battery is low Page 6 DC Page 13 and Page 16 AC Measurement display ("OL" is short for overload, indicates the reading exceeds the display range) Measuring units Page 11 Analog bar graph Measurement units Sign Description M Mega 1E+06 (1000000) k kilo 1E+03 (1000) m milli 1E–03 (0.001) µ micro 1E–06 (0.000001) n nano 1E–09 (0.
3.Quick Start Input terminals The terminal connections for the different measurement functions of the multimeter are described in the table below. Warning: Before starting any measurement, observe the rotary switch position of the multimeter, and then connect the test leads to the correct terminals. Caution: To avoid damaging the multimeter, do not exceed the rated input limit.
4.Making Measurements 4. Making Measurements Measuring AC or DC Voltage Warning: Do not measure any voltage of over 1000 Vdc or 750 Vac rms to avoid instrument damage or electric shock. Do not apply more than 1000 Vdc or 750 Vac rms between the common terminal and the earth ground to avoid instrument damage or electric shock. This multimeter displays DC voltage values as well as their polarity. Negative DC voltages will display a negative sign on the left of the display. DC voltage ranges are 60.
4.Making Measurements Testing Diodes Caution: To avoid possible damage to your multimeter or to the equipment under test, disconnect the circuit power and discharge all high-voltage capacitors before testing diodes. (1) Rotate the rotary switch to . Press once to enter diode testing mode, will be displayed. (2) Connect the black test lead to the terminal and the red test lead to the terminal.
4.Making Measurements Note: For the 4000 uF range, the measuring duration should be over 30 seconds. . Press (1) Rotate the rotary switch to three times to enter capacitance measuring mode, the Farad units will be displayed. (2) Connect the black test lead to the terminal and the red test lead to the terminal. (3) Probe the test points and read the display. Measuring Frequency Frequency ranges are 9.999 Hz, 99.99 Hz, 999.9 Hz, 9.999 kHz, 99.99 kHz, 999.9 kHz, and 9.999 MHz. .
4.Making Measurements (2) Connect the red connection of the K-type thermocouple to the and the black connection to the terminal. (3) Probe the test points and read the display. Press units between or terminal to change the temperature . Measuring DC or AC Current Warning: Never attempt an in-circuit current measurement where the open-circuit potential to earth is greater than 250 V. Doing so will cause damage to the multimeter and possible electric shock or personal injury.
5.Multimeter Features 5. Multimeter Features Data Hold Mode (1) Press to freeze the display during measurement, will be shown on the display. (2) Press again to exit this mode. Note: This function is not available when measuring diodes and transistor. Capturing Max. and Min. Values In MAX mode, the measured maximum value will be held; In MIN mode, the measured minimum value will be held. (1) Press to cycle between the MAX mode and MIN mode. (2) Press for more than 2 seconds to exit the mode.
5.Multimeter Features Buzzer Feature Press the function key, the buzzer will sound “Be…” in short. One minute before Auto Power-off the buzzer will sound “BeBeBeBeBe” five times to warn. Before it is shut off, the buzzer will sound a long ”Beee” then shut off. The buzzer will sound “BeBe…” continuously to warn when the measured DC voltage is higher than 1000 V, AC voltage is higher than 750 V, or the measured DC/AC mV mode is higher than 600.0 mV.
6.Bluetooth Function – B35(T) only 6. Bluetooth Function – B35(T) only B35(T) multimeter supports communications with Android based smart device through Bluetooth. You can use the free application software on the Android based smart devices to monitor the measurements, perform remote control, view trending graphs, etc. The recorded data can be saved as.CSV file. More than one meters can be connect simultaneously. Note: Bluetooth connectivity works over a range of about 10 meters.
6.Bluetooth Function – B35(T) only (3) Launch the application . (4) Click the icon on the top left of the screen to launch device connection. (5) If the Bluetooth function is activated, skip this step; if not, a dialog box will ask whether to turn on Bluetooth. Click "Yes". Click to scan for Bluetooth devices. (6) Click "OWON BDM*******" in the device list to pare. ("*******" is the serial number in the multimeter.
6.
6.Bluetooth Function – B35(T) only Function Description Table Display Function Display Function DC Direct Current CAP Measuring Capacitance AC Alternating Current Hz Measuring Frequency RES Measuring Resistance DUT Measuring Duty Cycle DIO Testing Diodes hFE Measuring Transistor BEEP Testing for Continuity TEMP Measuring Temperature Operations Customize the meter name The device name of meter can be customized.
6.Bluetooth Function – B35(T) only Upgrade Online: Click , and click "About", the following interface is shown. Click "Upgrade" as below. Click to upgrade Data Graph and Table: Click to view data graph and table. Click to show setting menu. Data DataGraph&Table Graph&Table Trending graph Data table Show menu Zoom Controls Setting menu: Softkey Description Open local file Read the saved file (.CSV) Save data Save the displayed data into .
7.Technical Specifications 7. Technical Specifications All these specifications apply to the multimeter unless otherwise explanation. Note: "T" in the model indicates true RMS (optional). Standard conditions: The environment temperature is 18℃ to 28℃, the relative humidity is less than 80%. Measurement Range Resolution Accuracy 60.00mV/600.0mV 60.00mV/600.0mV/6.000V/60.00V 600.0V/1000V 0.01 mV 0.1 mV 0.1 V ±(0.5%+2dig) 60.00mV/600.0mV 60.00mV/600.0mV/6.000V/60.00V 600.0V/750V 0.01 mV 1 mV 0.
7.Technical Specifications be over 30 seconds. [3] When measuring frequency, the typical waveform is Square or Sine. The signal meets the following conditions. Frequency Amplitude (rms) 1 Hz – 4 MHz ≥ 100 mV 4M–8M ≥ 200 mV 8 M – 10 M ≥ 300 mV [4] When measuring duty cycle, the typical waveform is Square or Sine.
8.Appendix 8. Appendix Appendix A: Enclosure Standard Accessories: Test lead Multi-functional K-type test socket thermocouple User Manual Options: Alligator clip Thin-tipped test lead Appendix B: General Care and Cleaning Warning: To avoid electrical shock or damage to the multimeter, ensure that the insides of the casing stay dry at all times. Cleaning To clean the instrument exterior, perform the following steps: Wipe the dust from the instrument surface with a soft cloth.
8.Appendix Appendix C: Fuse Replacement Use the following procedure to replace the fuse. position. Remove test leads and 1. Ensure that the rotary switch is at the any connectors from the input terminals. 2. Lift the tilt stand and loosen the screws with a suitable Phillips screwdriver and remove the battery cover. 3. Pry the fuse cover open using a straight screwdriver, replace the fuse. Use only the fuse of the specified rating (1 A / 250 V). 4.