User Manual
Table Of Contents
4.Making Measurements 
13 
4. Making Measurements   
Measuring AC or DC Voltage   
Warning: 
Do not measure any voltage of over 1000 Vdc or 750 Vac rms to 
avoid instrument damage or electric shock. 
Do  not apply more than 1000  Vdc or 750 
Vac rms between the 
common terminal and the earth ground to avoid instrument damage 
or electric shock. 
This multimeter displays DC voltage values as well as their polarity. Negative DC voltages 
will display a negative sign on the left of the display. 
DC voltage ranges are 60.00 mV, 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V; 
AC voltage ranges are 60.00 mV, 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 750 V.   
(1)  Rotate the rotary switch to 
  or  . Default is DC measurement mode,   
will be displayed. Press 
  to switch into AC measurement mode,    will be 
displayed. 
(2)  Connect  the  black test lead to the 
  terminal  and  the red test lead to the 
  terminal.   
(3)  Probe the test points and read the display.  Press 
  to  enable and cycle 
through the manual ranges.   
Measuring Resistance   
Caution
: To avoid possible damage to your multimeter or to the equipment under 
test, disconnect the circuit power and discharge all high-voltage 
capacitors before measuring resistance. 
Resistance ranges are 600.0 Ω, 6.000 kΩ, 60.00 kΩ, 600.0 kΩ, 6.000 MΩ, and 60.00 MΩ.   
(1)  Rotate the rotary switch to 
.   
(2)  Connect the  black test lead to the 
  terminal  and the red test lead to the 
  terminal.   
(3)  Probe the test points and read the display.  Press 
  to enable and cycle 
through the manual ranges.   