Note: For the 4000 uF range, the measuring duration should be over 30 seconds. 
(1)  Rotate the rotary switch to 
.  Press    three times to enter capacitance 
measuring mode, the Farad units will be displayed. 
(2)  Connect the  black test lead to the 
  terminal  and the red test lead to the 
  terminal.   
(3)  Probe the test points and read the display.   
Measuring Frequency 
Frequency ranges are 9.999 Hz, 99.99 Hz, 999.9 Hz, 9.999 kHz, 99.99 kHz, 999.9 kHz, and 
9.999 MHz.   
(1)  Rotate the rotary switch to 
.   
(2)  Connect the  black test lead to the    terminal  and the red test lead to the 
  terminal.   
(3)  Probe the test points and read the display.   
(4)  Press 
  to switch between the frequency and duty cycle measurements.   
When measuring  AC  voltage or  AC  current, press 
  to  cycle through  frequency 
measuring, duty cycle measuring, and original measuring.   
Measuring Transistor   
Warning: To avoid electrical shock or damage to the instrument, do not apply 
more than 250Vdc or 250Vac rms between the 
terminal and 
the 
  terminal.   
(1)  Rotate the rotary switch to  .   
(2)  Connect  the “+” plug  of the multi-functional  test  socket  to the 
  terminal 
and the “COM” plug to the 
  terminal).   
(3)  Determine whether the transistor is NPN or PNP type and locate the Emitter, Bas e 
and Collector leads. Insert leads of the transistor into the corresponding holes of the 
multi-functional test socket. 
(4)  Read the hFE value.   
Measuring Temperature 
(1)  Rotate the rotary switch to  .   