J801X Technical Specs

100% fired and tested: All units and each component
are tested on the manufacturing line.
Low Boy Height: Easy to apply in low ceiling applications,
works well with taller high SEER coils, easier to handle
and install.
Tubular primary heat exchanger: Heavy gauge
aluminized steel heat exchanger assures a long life.
30 second blower delay at start-up: Assures a warm
duct temperature at furnace start-up. Adjustable blower
off settings (60, 90, 120 and 180 seconds).
30 second post purge: Increases life of heat exchanger.
Hot surface igniter: Innovative application of a silicon
nitride igniter. Utilizes proven Smartlite
®
technology.
High static blowers: All models equipped with high static
blowers.
90 second cooling cycle blower-off delay (TDR):
Increases cooling performance.
Flexible category I venting system: May be vented with
dedicated venting system or common vented with other
category one appliances.
High efficiency blower kits: Maximize efficiencies. On
select units, a SEER improvement of up to 1 point is
realized.
Multi-speed direct drive blower: Designed to give a wide
range of cooling capacities. Switches on PCB, provide
ultra easy motor speed selection.
LP convertible: Simple burner orifice and regulator spring
change for ease of convertibility.
Diagnostic lights for easy troubleshooting without
counting flashes: Dedicated light for flame signal strength
and 2 lights in combination to indicate all other fault codes
with easy to recognize states without counting flashes.
Integrated control board: Incorporates connections for
electronic air cleaner and humidifier.
Two piece door design: Enhances furnace appearance
and uses captured screws to prevent loose door screws.
Blower Compartment: Insulated for ultra quiet operation.
Meets Title 24 Standards: Min. 350 CFM/Ton, .58 watts/
CFM and 2% cabinet leakage.
Meets SCAQMD and SJVAPCD rules 1111/4905: For
low NOx limit of 40ng/J.
Induced Draft - 80+% AFUE
Input 45,000 - 126,000 BTUH
J801X* Series
High Efficiency Upflow/Horizontal and
Downflow Gas Furnaces
The high efficiency gas furnace may be installed free
standing in a utility room, basement, or enclosed in an
alcove or closet. The rounded corner jacket provides a
pleasing “appliance appearance.” Design certified by CSA
for application in Canada and the United States.
FEATURES and BENEFITS
TECHNICAL
SPECIFICATIONS
This furnace series is approved and certified by the
SCAQM and the SJVAPC Districts in the state of California
under each Districts’ Mitigation Fee Plan for shipment into
and sales in both districts.
For California installations in SCAQMD only: This furnace
does not meet the SCAQMD Rule 1111 NOx emission limit
(14 ng/J), and thus is subject to a mitigation fee of up to
$450. This furnace is not eligible for the Clean Air Furnace
Rebate Program: www.CleanAirFurnaceRebate.com.