Operation Manual
55
E 10
E 11
E 12
Caution: The supply
voltage drops
considerably during the
rotation of the antenna.
Recharge the battery as soon as
possible. Check the wiring and the
connection of the system to the
voltage supply. Observe the
i
nformation in the Installation
Instructions!
E14
E 15
Incorrect feedback from
antenna unit.
An incompatible antenna unit is
connected.
The power relay of the antenna unit
does not hold or the contacts are
contaminated or defective (relay
fault).
Potentially strong switch transients
of the power supply (external supply
by charge controllers or interferences
from TV sets).
E 16
Incorrect model
configuration.
Error occurred during model
configuration. An update may have
been performed incorrectly. The
system must be serviced by the
manufacturer.
E 17
Re-Init activated. Corrupt memory detected. The
faults were corrected.
Switch the system off and back on.
You may have to change some
settings (e. g. search satellite).
E 18
Limit switch/mechanical
fault
A fault in the antenna unit has been
detected. Icing may be the cause.
Please contact the service
department.
E 19
Hardware fault
(possibly in con
j
unction
with OSD message)
The automatic self-test revealed a
hardware fault. Do not operate the
system any more, further damage
may occur. The system must be
returned to the service department.