4. Main Technical Parameters (Table 1)
Project
Unit
Technical
Indicators
Conditions
Nominal Voltage
V
3.0
CR series batteries only
Nominal capacity
MAh
210
Continuous discharge at
15.0 kload
Instantaneous short
circuit current
MA
≥ 300
Time ≤ 0. 5 '
Open Circuit Voltage
V
3.25
~
3.45
All CR Series Batteries
Storage temperature
0
~
40
All CR Series Batteries
Applicable
temperature
-20
~
60
All CR Series Batteries
Standard Weight
G
Approximately 2.9g
Only for this series of
batteries
Self-discharge rate
%/year
2
Only for this series of
batteries
Quick Test
Initial
Period
H
≥ 66.7
At a
load of 1.0 k and a
temperature of 20
Service Life
± 2 ℃, relative
humidity ≤ 75% RH
12 months
later
H
≥ 65.3
Under the
circumstances.
Note 1: The electrochemical system and size of this product shall comply with IEC 60086-
1: 2007 (i.e. GB/T8897.1-2008, original electricity
Pool, Part 1: General).
5. Product
Specifications and
Testing Methods
Unless otherwise specified, all tests of the product shall be
carried out under the following conditions:
(1) Ambient temperature: 20 ± 5 ℃.
(2) Relative humidity: 60% RH ± 15%.