SDS

Table 2
Test Items
Test Method
Quality standard
Test and test
with vernier caliper with
accuracy not less than 0.02 mm
Diameter (mm): 20.0 (
-
0.20)
1. Outline
dimensions
Insulation materials should be pasted
on the contact surface of calipers to
prevent
Height (mm): 3.20 (
-0.20)
Short circuit.
2. Open Circuit
Voltage
Use numbers with accuracy not less than
0.25% and internal resistance greater
than 1M
3.25
~
3.45 V
Multimeter.
Test with pointer multimeter, each
time
for no more than
3. Instantaneous
short circuit
current
0.5 ', but it is necessary to avoid
repeating the test and testing the time
again.
≥ 300 mA
The interval should be more than
0.5 hours.
Clean
and tidy, clearly
marked, without
deformation,
Rust, leakage.
Installed in-use device
4. Appearance
Purpose
Measure
In the device, the two
poles of the battery
should always
The ability to form and
maintain good contact
Yes.
5. Rapid discharge
capacity
At standard temperature 20 ± 2 ℃,
relative humidity ≤ 75% RH, negative
≥ 66.7 hours
When the load is 1.0 k and the
termination voltage is 2.0 V.
6.
Vibration test
On a vibrating machine with a vibration
frequency of 100
-150 times per minute
Stable performance
Continuous vibration
for 1 hour.
7. Liquid leakage
resistance at high
temperature
Stored at 45 ± 2 ℃ for 30 days.
Leakage rate ≤ 1/10000
8. Overdischarge
leakage resistance
When the termination voltage reaches 2.0
V, the discharge is continuously
discharged for 5 hours.
No leakage
Can
Note 2: The overall dimensions and performance of this product comply with IEC 60086-
2: 2007 (i.e. GB/T8897.2-2008, Primary Battery,
Part 2: Requirements for overall
dimensions and electrical properties).
Note 3: