User Manual

Installer Facilities
17047 Ver 1.8 DRAFT C 23 Easikey® 1000
Step Sending Unit Receiving Unit Action
1 Present an editor key to each controller
reader.
2
SEL? SEL?
Press INST/9 at each controller.
3
SetC SetC
Press Ð at each controller.
4
in in
Press Ð again at sending controller only.
5
oUt in
To start the transfer:
Press SEL/SAVE twice on the receiving
controller then:
Press SEL/SAVE twice on the sending
controller.
6
oUt / nnn in / in The sending controller will display oUt
alternating with the percentage complete.
The receiving controller will flash
in.
When complete, both displays will return
to
SEL?
7
SEL? SEL?
Press ESC to leave Editor mode.
8.3 Editor Keys
This function is fully described in Section 13.
8.4 Channel Interlock
When a reader is used on both sides of a door to monitor both entry and exit, it is only
necessary to feed one lock. The same lock, lock 1, will be operated by both reader 1 (entry)
and reader 2 (exit). Lock 2 is not used. Door monitoring and RTE, if used, are on channel 1.
Step Example Display Action
1 Present an editor key to the controller reader.
2
SEL?
Press INST/9.
3
SetC
Press Ð 4 times.
4
P00
Press Î to toggle Channel Interlock ON/OFF
5
P00.
6
SEL?
Press ESC to leave Editor mode.