5.3 Other Connections
This section describes the relay outputs, enclosure tamper, override input, and auxiliary power output. All
these connections are made at removable terminal blocks along the bottom and left edge of the circuit
board.
Also included in this section are brief details on the alarm event manager. This can be connected to any
door controller but is primarily used in conjunction with the PAC Portico 2204 Alarm Controller.
5.3.1 Relay Outputs
There are 8 relay outputs fitted to the left-hand edge of the door controller, each consists of a removable
terminal block with Common, Normally Open and Normally Closed contacts. When a relay is activated the
contact changes over from NC to NO. Depending on the type of administration system, these relays can
be programmed to operate as a result of particular events happening.
Each relay is capable of switching 12V at 1A or 24V at 0.5A.
Figure 26 Relay Outputs
Without any programming, they will respond as follows:
Relay 1
Operates in the event of an invalid key being presented on door 1.
Relay 2
Operates in the event of an invalid key being presented on door 2.
Relay 3
Operates in the event of an invalid key being presented on door 3.
Relay 4
Operates in the event of an invalid key being presented on door 4.
Relay 5
Operates in the event of an Unauthorized Access at any door on the door controller.
Relay 6
Operates along with time profile 1.
Relay 7
Operates in the event of a Door Left Open at any door on the door controller.
Relay 8
Operates in the event of an enclosure tamper (see Section 5.3.2).
Notes
1. The above default settings are applied when the controller database is initialized either at the
front panel or via a PC. Default settings will also be applied automatically when upgrading from a
2100/1100 Series to a PAC Portico 2200/1200 Series.
2. PAC Portico for Windows can override the default settings for the first four relays. Relays 5-8
cannot be changed from their default settings.
3. PAC Portico Prism can override the default settings for all eight relays.