15263 Ver 2.1 DRAFT E PAC Portico 2200/1200 Series Installation Guide
Page 52 © 2003 Blick USA, Inc.
WARNING
ANY FAILURE OF THE DOOR CONTROLLER OR CABLING WILL PREVENT THIS MEANS OF
RELEASING THE DOORS FROM WORKING. THEREFORE THIS INPUT MUST NOT BE
CONSIDERED AS A PRIMARY SAFETY MECHANISM - see Section 5.2.5.
5.3.4 Auxiliary Power Output
This connection can be used to provide power for auxiliary equipment. The electrical rating for the
auxiliary output is 500mA @ 12V and 250mA @ 24V.
Note
The auxiliary power output is not available on the PAC Portico 2200IP/1200IP Series.
5.3.5 Auxiliary Serial Port
The auxiliary serial port is labeled SPARE and can be used to connect a DMP alarm panel.
5.3.6 Alarm Event Managers
An Alarm Event Manager (AEM) is a device that connects to a reader channel between the controller and
the reader. Each AEM allows 8 supervised points to be monitored and provides 8 relays for
programmable responses.
Further details are given in the documentation supplied with the Alarm Event Manager.