6.3.5 INST Command
This command can be used at any time to change settings. It is also entered automatically after the
SYSTEM START command.
The prompts displayed depend on the type of system being installed.
6.3.5.1 Ver 1
E0 KEY 00000000
This is where the master key code will appear, there may already be a code
here - it will consist of numbers 0-9 and letters A-F.
Present a key to the front panel reader.
E0 KEY 3A33642A
The key code will appear, replacing what was previously displayed.
Press NXT five times to go on to the next stage.
For a Master Controller:
ENTER SYS TYPE 2
Type 2 and press ENT.
Press NXT to continue
BAUD RATE 9600
For a controller attached to a PC interface kit (system type 2) the baud rate
should be 9600.
For a controller attached to a CNC (system type 2) the baud rate depends on
the RS-232 devices being used - modems, line drivers, etc: 300,1200,
2400, 4800, 9600.
Enter baud rate and press ENT.
For a Slave Controller
ENTER SYS TYPE 3
Type 3 and press ENT.
Press NXT to continue
ADDRESS 2
Enter the controller address, 2 - 8 (by default, 1 is the address of the master.
Note
The option of setting a baud rate does not appear when the system type is 3.
6.3.5.2 Ver 2
For a Direct master:
PC ADMIN USED _
Type N for standalone.
Press ENT then NXT.
PC MASTER DC _
Type Y for standalone master.
Press ENT then NXT.
E0 KEY 00000000
This is where the master key code will appear, there may already be a
code here - it will consist of numbers 0-9 and letters A-F.
Present a key to the front panel reader.
E0 KEY 3A33642A
The key code will appear, replacing what was previously displayed.
Press NXT.
For a standalone slave:
PC ADMIN USED _
Type N for slave.
Press ENT then NXT.
PC MASTER DC _
Type N for slave.
Press ENT then NXT.
ADDRESS 1
Type 2, 3 or 4.
Press ENT then ESC.