FRGT FREE EXIT N
Leave as N for reporting Free Exit events; type Y to ignore these
events.
Press ENT then NXT.
FRGT TIME EVNT N
Leave as N for reporting Time events; type Y to ignore these events.
e.g. Automatic Lock and Auto Zone Disable.
Press ENT then NXT.
FRGT POS TRANS N
Leave as N for reporting Positive Transaction events; type Y to
ignore these events, e.g. Access Authorized, Entry
Authorized, Exit out of Hours and Exit Authorized.
Press ENT then NXT.
FRGT NEG TRANS N
Leave as N for reporting Negative Transaction events; type Y to
ignore these events, e.g. No Access : 'reason' events.
Press ENT then NXT.
DIAL D/C1 DR----
Type the door numbers (reader channel numbers) for which dial-back is
to be initiated in the case of a Positive Transaction event on door
controller 1 (the door controller the dial-up device is connected to).
For example, if a dial-back to be initiated when a positive event occurs
on doors 1 and 3 on door controller 1, type 1 and 3.
Press ENT then NXT.
DIAL D/C2 DR----
As above for door controller 2.
DIAL D/C3 DR----
As above for door controller 3.
DIAL D/C4 DR----
As above for door controller 4.
DIAL D/C5 DR----
As above for door controller 5.
DIAL D/C6 DR----
As above for door controller 6.
DIAL D/C7 DR----
As above for door controller 7.
DIAL D/C8 DR----
As above for door controller 8.
Press ESC.
In order for dial-back on Positive Transaction events to operate a number of other settings
need to be programmed:
In Modem Configuration mode, the following must be programmed:
CONNECT MODEM Y
Make sure that Y is programmed to indicate there is a dial-up modem
connected to this door controller.
SETUP -D------
Make sure that the D setting is programmed to enable dial-back. In the
event of an alarm condition, the door controller will dial-back to the Multi-
Site CNC. If a dial-back on Positive Transaction events is also
required, the additional settings described above must also be
programmed.
In Forget Transaction mode, the following must be programmed:
FRGT POS TRANS N
This setting must be programmed to N in order that all positive
transactions are not ignored and hence initiate dial-back to the CNC.