Number Description Priority Dial-Back? Forget?
8
Request for Entry
A special lock mode option can be used to allow a
Request for Entry transaction. This may be used
when a button is used from inside an area to allow a
person access.
RTE
9
Unauthorized Access
A door has been opened without a key being
presented or the Request to Exit being pressed.
high yes
10
No Access: Level
A key has been presented, but is not allowed through
this door.
high negative
11
No Access: Locked Out
A key has been presented, but it is not been given
any access authority.
high negative
12
No Access: Time
A key has been presented, but is not allowed through
this door at this time.
high negative
13
No Entry: Passback
A key has been presented, but will not allowed
through this door until it has left the pass-back area.
high negative
14
No Access: Holiday
A key has been presented, but a holiday period has
been assigned to this key.
high negative
15
Door Left Open
A door has been left open beyond the time allowed.
high yes
16
Door Closed
A door has been closed after being left open.
high yes
17
Anti-Tamper Alarm
A reader has been disconnected or its cable has
been broken.
high yes
18
Alarm Cleared
A door has been secured after an Unauthorized
Access or a reader/cable has been restored after an
anti-tamper alarm.
high
19
Override Alarm
An override alarm has opened all the doors attached
to the door controller.
high yes
20
Override Alarm Reset
The override input has been cleared, all the doors
will close again.
high
21
Manual Lock
An operator has manually locked a door open on a
time profile, or previously opened manually.
high
22
Manual Unlock
An operator has manually unlocked a door.
high
23
Automatic Lock
A door has automatically locked on a time profile.
time
event
24
Automatic Unlock
A door has automatically unlocked on a time profile.
time
event