User Manual

15263 Ver 2.1 DRAFT E PAC Portico 2200/1200 Series Installation Guide
Page 72 © 2003 Blick USA, Inc.
Number Description Priority Dial-Back? Forget?
42
Local Duress Alarm Acpt
A PIN Duress Alarm has been accepted by an
operator at the door controller.
high
44
Remote RTE
A door has been temporarily unlocked by the PC
administration system.
low
45
No Exit: Passback
A key has been presented, but will not allowed
through this door until it has entered the pass-back
area.
high negative
46
Exit Out of Hours
A key has been allowed to pass through an exit door,
although a time profile would not normally let the key
through. A special lock mode option needs to be set
on the door to allow this feature.
positive
47
Editor Off (Panel)
An operator has left the Editor mode, or it has timed
out, at the faceplate-administrated system.
48
Editor On (Panel)
An operator has entered the Editor mode at the
faceplate
49
Power Off
The door controller has had its power removed, or
the Reset button has been pressed.
high yes
50
Power On
The door controller has been powered up, or the
Reset button has been released.
high
54
Incorrect PIN Entry
A keyholder has made 5 attempts to enter a PIN
without success. That key will not be accepted for 2
hours.
high negative
55
Manual Relay Reset
A relay, either on the door controller or an Alarm
Module, has been reset by an operator. This may
occur by disabling a time profile controlling the relay,
or switching off the relay record itself.
56
Manual Relay Set
A relay, either on the door controller or an Alarm
Module, has been set by an operator. This may occur
by enabling a time profile controlling the relay, or
switching on the relay record itself.
57
Auto Relay Reset
A relay, either on the door controller or an Alarm
Module, has been reset by a time profile.
time
event
58
Auto Relay Set
A relay, either on the door controller or an Alarm
Module, has been set by a time profile.
time
event
59
Zone Tamper Alarm
A zone on an Alarm Event Manager has been
tampered (open circuit).
high yes