User Manual

15263 Ver 2.1 DRAFT E PAC Portico 2200/1200 Series Installation Guide
Page 74 © 2003 Blick USA, Inc.
Number Description Priority Dial-Back? Forget?
80
Dial-Back Failure
A door controller failed to get through to Multi-Site
CNC.
86
Local Override Accept
A door controller override alarm has been accepted
at the faceplate
89
No Access: Armed
A user with invalid alarm privileges has tried to
access an area that is armed. Reports the name of
the user and the door where it occurred.
high negative
90
Alarm Perimeter Armed
The boundary of a building has been armed on a
Radionics alarm panel (only available when K2050
Alarm Integration Module and EPROM 13038 fitted.
91
Alarm Full Armed
All alarm areas of the building have been armed on a
Radionics alarm panel (only available when K2050
Alarm Integration Module and EPROM 13038 fitted.
92
Alarm Disarmed
All alarm areas of the building have been disarmed
on a Radionics alarm panel (only available when
K2050 Alarm Integration Module and EPROM 13038
fitted.
high
95
External Inhibit On
Access through doors has been inhibited by the
INHB/DR3 input going active. Reports the door and
the alarm area (if assigned) affected.
high
96
External Inhibit Off
Access through doors is now permitted after
INHB/DR3 input has gone inactive. Reports the door
and the alarm area (if assigned) affected.
high
97
Auto Inhibit Active
A door has been inhibited by an area being armed
(only available when intelligent alarm panel fitted).
Reports the door and the alarm area affected
high
98
Auto Inhibit Removed
A door inhibit has been removed by an area being
disarmed (only available when intelligent alarm panel
fitted). Reports the door and the alarm area affected
high
99
Panel Manually Armed
An intelligent alarm panel has been armed via its own
keypad. Reports the alarm area affected.
100
Panel Manually Disarmed
An intelligent alarm panel has been disarmed via its
own keypad. Reports the alarm area affected.
101
Area Armed
An intelligent alarm panel has confirmed an area
being armed via the door controller arming readers or