10.4 'Forget' Transactions
The door controller can be programmed not send certain groups of transactions. You can choose which
of the following groups are not sent.
Request to Exit
These transactions may form 40-50% of all the
transactions in a system. By allowing the door controller
to 'forget' these events, the throughput of more significant
transactions can be improved.
7 Request to Exit
8 Request for Entry
Free Exit
This transaction allows free exit through a door.
4 Free Exit
Timed Events
These are reports of events that happen automatically as
a result of a time profile being applied.
23 Automatic Lock
24 Automatic Unlock
29 Auto Zone Disable
30 Auto Zone Enable
57 Auto Relay Reset
58 Auto Relay Set
Positive Transactions
These are records of normal key usage. By allowing the
door controller to 'forget' these events, throughput may be
considerably improved.
Note
Some administration system functions such as
presence in area, muster mode, current user, etc.
along with other functions that rely on detecting the
movement of personnel, will not work if these
events are not sent.
1 Exit Authorised
2 Entry Authorised
3 Access Authorised
46 Exit Out of Hours
Negative Transactions
These are records of key usage where access was
denied. By allowing the door controller to 'forget' these
events, throughput can be considerably improved.
10 No Access: Level
11 No Access: Locked Out
12 No Access: Time
13 No Entry: Passback
14 No Access: Holiday
32 No Access: Visit Time
39 Repeated Token Use
40 PIN Reader Duress Alarm
45 No Exit: Passback
54 Incorrect PIN Entry
89 No Access: Armed