11. Specifications
11.1 Environmental
Door Controller
Temperature
0ºC to +40ºC
Humidity 0% to 90% RH (non-condensing)
Readers
Temperature
-40ºC to +40ºC
Humidity 0% to 90% RH (non-condensing)
11.2 Power Supply
The PAC Portico 2200/1200 Series Door Controllers has an integral mains power supply. It is capable of
automatically sensing the input voltage and will therefore operate on a 110-120V or 220-240V, 50Hz or
60Hz ac power supply without the need for switch setting.
The lock output is switch selectable between 12V dc and 24V dc. The lock output voltage applies to all
the lock outputs.
Note
The switch selection affects locks, the battery charging output and the auxiliary output.
Electrical rating for the auxiliary output is 500mA @ 12V and 250mA @ 24V. The auxiliary output is not
available on the PAC Portico 2200IP/1200IP Series.
Full load power heat dissipation is 26W @ 250V ac and 115V ac door controllers.
Battery capacity for emergency standby at least 40 minutes when using two 12V, 7Ah batteries.
AC Line Input
Voltage 85V ac to 250V ac 50/60Hz power input
Fuse Rating 3.15A 20mm HBC fuse (in ac connector) for 4A PSU
5A 20 mm HBC fuse (in ac connector) for 8A PSU
Connector Standard IEC connector, right angle socket supplied
Lock Output
Output Voltage 12V dc or 24V dc, switch selectable.
Fuse Rating Re-settable fuse on board, one per channel
Max. Current 1.0A per channel at 12V dc
0.5A per channel at 24V dc
Battery Backup
Input Voltage 12V dc or 24V dc, depending on lock output
Fuse Rating Re-settable fuse on board
11.3 Cable
Reader Cable
Type 6 conductor, multi-stranded, unshielded cable
Distance/Gauge Up to 250m:0.22mm² Up to 750ft: 24 AWG
Up to 500m:0.50mm² Up to 1500ft: 20 AWG
Up to 1000m:1.00mm² Up to 3000ft: 18 AWG
Lock Output
Type 2 conductor, multi-stranded
Distance/Gauge Depends on distance to lock and the current drawn by the lock.
Usually 0.5mm² or 1.0mm² / 20 AWG or 18 AWG will be sufficient.
Six Wire Bus
Type 6 conductor, multi-stranded, unshielded cable.
Distance Overall length of bus (max):1000m/3000ft
Between controllers (max): 500m/1500ft
Gauge 24 AWG/0.22mm²
11.4 Mean Time Between Failures
>100,000 hours