User Manual

PAC Portico PIN Reader Installation Guide 15826 Ver 1.8
DRAFT C
© 2003 Blick USA, Inc Page 3
Surface Mounted
The reader is designed to be surface mounted onto a flat surface using the two holes provided,
therefore not requiring the installation of a back box. The readers performance is unaffected by
the material of the mounting surface. Ensure the surface is as even as possible to provide
maximum protection against the reader being levered from the wall.
The connecting cable can be taken via the hole provided on the lower section of the reader
housing and then surface mounted, preferably under the protection of a suitable conduit.
Alternatively, the cable could be taken directly from the terminals through a suitably prepared
hole in the mounting surface so as to be completely hidden from sight.
The holes are designed to accept size No.8 countersunk screws, preferably anti-tamper type, with
a recommended minimum length of 2in/50mm. This recommended length of course depends on
the surface type and construction.
The dimensions of the surface mounted reader are 8in/200mm x 4in/100mm x 1.3in/30mm.
Connections
Reader Connections
The connections for both readers are:
Color Signal Notes
Black 0V Negative supply
White SIG Reader signal
Brown VCA Valid code accept LED
Red +12V Positive supply