User's Manual

4
Wiring
All connections are made to the flying lead using the 10 cable crimps provided. Cable gauge
depends on distance from the Door Controller to Reader. The flying lead is 3 ft (1m) long and has
a gauge 24AWG (0.22mm
2
).
With 24AWG (0.22mm
2
) cable twist the wires and double them over before inserting them in the
crimps. This includes the flying lead.
Flying
Lead
PAC
Black GND
White SIG
Green Not Used
Brown VCA/LED
Yellow SOUNDER – GND to activate
Red 12V DC (+10.5 to +20V)
Blue TAMPER
Typical PAC Door Controller Wiring
PAC Door Controllers to PAC DualTech Readers can be wired as follows:
Caution:
Always consult your door-controller instructions before wiring a reader.
-V or GND
SIG
+V
LED
DC or DR1
RTE or DR2
N/O
N/C
Door Contact
Request to Exit
Reader
Door
Controller
Red
Brown
White
Black
Blue
N/O
Yellow
Sounder Switch
SOUNDER
TAMPER
+12V
VCA/LED
0V
SIG
Note:
Always refer to your controller manual before connection.