User guide

• Talk Time
• Personal Access Code
• Call Forwarding automatic or manual
Technical Specifications:
Power Input: 12VAC 20VA UL Listed Transformer (Pach supplied) or 12.0 VDC 20VA
Current Consumption: 420mA idle, 620mA operation
Emergency Battery: 12.0 VDC, 4Ahr rechargeable (not supplied)
Night Light: 14V 0.080A 15,000 Average life hours
Telephone Line: Standard voice grade RJ11 jack
Operating Environment: Temp. -32°F to +140°F Relative Humidity 0% to 95% non-condensing
Relay Output: Two Relays to control two doors independently. Form C Dry Contact 120 VAC 10A/24VDC 10A/250VAC 7A
Memory Type: EEPROM
Tone Detection: Crystal controlled, capable of detecting short bursts 80 ms
Mounting: Surface Mount
Construction: 16 Gauge Stainless Steel
Shipping: 8 lbs. or 3.6 kg. approximate
Dimensions: 9-1/8” (23.2Cm) x 6-15/16” (17.2Cm) x 3-7/8” (9.8Cm) (HWD)
1.5 Options and Accessories
Visit our website www.pach-co.com or call 1-888-678-7224
1.6 Unpacking the System
Check the serial number on the printed circuit board, cabinet and warranty card, they must match. If they do not match,
please contact Pach and Company toll free number at (888) 678-7224. All the items listed below come with the AeGIS 4000
Series.
AeGIS 4000 Series System.
• XMFR (Power Transformer, 12VAC 20VA).
• Two of 5-pin terminal connector (inside the unit’s cabinet).
• 7-pin terminal connector (inside the unit’s cabinet).
• Key set (2 keys per set)
• Interceptor Module.
• Owners Manual.
• Warranty Card with unit’s serial number.
If you have missing items, please contact Pach and Company at (888) 678-7224.
Pach and Company Page 2
AeGIS 4000 Chapter 1. Getting Started