6. CHARGE STATUS INDICATOR
The CHARGING and FULLY CHARGED LEDs will illuminate and flash in various
patterns to indicate the different stages of charging. See below for flash patterns.
Note: : SOLID FLASH EXTINGUISH
POWER ON LED: Red LED illuminates (solid) when power on.
CHARGING LED: Yellow LED illuminates and flashes when 7-stage charging
process.
FULLY CHARGED LED: Green LED illuminates (solid) when fully charged.
FAULT LED: When Red LED illuminates and flashes, it may be caused by:
1. Reverse connection between positive and negative of the DC lead.
2. Battery charger output short.
3. Non battery link.
4. 12V charger connects to a battery voltage higher than 17.5V or 24V charger
connects to a battery voltage higher than 35V.
O
5. Charger's internal temperature is higher than 70 C
6. When Red LED flashes and Yellow LED illuminates (solid) means bulk
charging has timed out and stopped after 24 hours.
: :
Power Off
Power On
Charging
1. Desulphation
2. Soft Start
3. Bulk
4. Absorption
5. Battery Test
6. Recondition
7. Float
Fully Charged
Non Battery Link
Protection
Output Polarity Reverse
Protection
Output Short Protection
Over Voltage Protection
Faulty Battery
Thermal Protection
Red LED
Power On
Yell LED
Charging
Green LED
Fully Charged
Red LED
Fault
(Bulk Led)