Operation Manual

7. SPECIFICATIONS
Charger type
Input Voltage
Input Power
Output Voltage
Output Current
Minimum Start Voltage
Desulphation
Soft Start
Bulk
Absorption
Battery Test
Recondition
Float
Efficiency
Thermal Protect
Ambient temperature
Over Voltage Protection
Deep Cycle
Types of Batteries
Dimension(LxWxH)
Weight
7-Stage automatic 7-Stage automatic 7-Stage automatic 7-Stage automatic
123W
12V DC
4A
2V
250VAC, T3.15A 250VAC, T3.15A 250VAC, T3.15A 250VAC, T3.15A
154W
12V DC
5A
2V
215W
12V DC
7A
2V
307W
12V DC
10A
2V
Pulse charge up to 11V
Half the rated set current up to 12V
4A (Up to 14.4V)
Constant
voltage until
current drops
to 0.6A
5A (Up to 14.4V)
Constant
voltage until
current drops
to 0.75A
7A (Up to 14.4V)
Constant
voltage until
current drops
to 1.05A
10A (Up to 14.4V)
Constant
voltage until
current drops
to 1.5A
Monitors voltage for 90 seconds
Constant
current (0.6A)
for 4 hours
limited to 16V
Constant
current (0.75A)
for 4 hours
limited to 16V
Constant
current (1.05A)
for 4 hours
limited to 16V
Constant
current (1.5A)
for 4 hours
limited to 16V
13.8V also with pulse feature
App.85%
65 +/-5
O O
C C
-20 to +50, output power is reduced automatically at high temperatures
The 12V charger will automatically if the voltage is higher than 17.5V.protection
30-80 35-100Ah
50-140Ah 70-200Ah
Most types of lead acid batteries including Calcium, GEL and AGM
195x115x62mm
1.0Kg
195x115x62mm 195x115x62mm 195x115x62mm
1.03Kg 1.05Kg 1.07Kg
BATTERY RANGE
P/No. MBC 1204 MBC 1205 MBC 1207 MBC 1210
Current Fuse Rating
Current Fuse Rating
250VAC, T3.15A 250VAC, T3.15A 250VAC, T3.15A 250VAC, T3.15A
220-240V, 50/60Hz 110V, 50/60Hz
Specifications are subjected to change without prior notice.
7
Cooling Fan
Automatic temperature controlled