Operation Manual
BA SC24 M; GB - 22520 - 2008.08-01
Programming manual SC 24 
In mode AUTO manual 
switching possible by 
pressing relevant key
1  ⇒ Monday 
2  ⇒ Tuesday 
3  ⇒ Wednesday 
4  ⇒ Thursday 
5  ⇒ Friday 
6  ⇒ Saturday 
7  ⇒ Sunday 
⇒ Channel ON
  ⇒ Channel OFF 
⇒ IMPULSE 
     01 - 59 sec.
Programming 
Key functions 
 [ Menu ] Selection of programming modes 
AUTO → PR → ? →   → S/W → AUTO ... 
[ CL ]  Cancelling of inputs in modes 
PR; ? and  . 
[
◆]  In PR; ?;
and S/W modes: 
  Change flashing digit resp. position. 
  In Mode ?: 
  Change selected inputs. 
[ O.K.] Confirm the selected mode. 
  In PR and
modes: 
Head for required position. (forwards) 
In? mode: 
Head for next switching time. 
In S/W mode: 
Enter into memory. 
[◄]  In PR and
modes: 
Return to required position. (backwards) 
In PR mode: 
Head for holiday programme when 1 (Monday) 
is flashing. 
In ? mode: 
Return to switching time before. 
[ A ]  In AUTO mode: 
  Press for manual override ON or OFF. 
Holding down key for 3 seconds, will switch ON 
or OFF PERM override. perm will be displayed. 
Programmed function in relevant channel will 
be suppressed.   
  Cancel permanent ON or OFF by holding down 
key for a further 3 seconds, perm will disappear. 
Programming advice 
The default setting on delivery is programmed real 
time and date, the summertime change is activated. 
Programming possible also with time switch 
disconnected: Press O.K., display appears, start 
programming. 
Make inputs step by step. The appropriate position in 
the display is flashing and can be changed by pressing 
◆ key. Head for next position by using O.K. key, go 
backwards by using ◄ key. Inputs are terminated 
when flashing finishes. 
Installation details 
The installation and assembly of electrical 
equipment must be only carried out only by a 
skilled person.
Connect to voltage and frequency according to type 
label only. 
Warranty void if housing opened by unauthorised 
person. 
The high density electronic circuit is protected against 
a wide range of external influences. Incorrect operating 
may occur if external influences exceed certain limits. 
Operating modes 
AUTO Display of time, day of week, switch status of 
channel(s). Also indication of actual day’s 
programme in full hours. 
2 – channel – version: Change of the indication 
channel A/channel B every 10 seconds. 
Manual overriding possible (KEY A, B) 
PR  Input of switching commands according to 
week day(s) and time, also the holiday 
programme 
Use arrow ◄ and O.K. keys to alter flashing digit. 
Use diamond 
◆ key to increase value. 
(Confirm last input with O.K. key, will enter into 
memory) 
  If Monday 1 is flashing, use the ◄ key to 
select the holiday programming. 
?  Displays number of free memory locations 
Show switching times 
Alter switching time 
Clear single or all switching times 
Use O.K. key forwards or ◄ key backwards to 
display switching times. 
Use diamond 
◆ key to change (alter) 
displayed switching time. 
Use CL key to cancelling the displayed 
switching time. 
Use CL key twice to cancel all switching times if 
number of free memory locations available 
displayed only. 
  Input of actual date and time 
Use arrow ◄ and O.K. keys to alter flashing 
digit. 
Use diamond ◆ key to increase value. 
(Confirm last input with O.K. key, will enter into 
memory and change into AUTO mode) 
S/W  To activate / deactivate the summer/winter 
time change over. 
Use diamond 
◆ key to select automatic S/W – 
time change ON or OFF. 
(Confirm last input with O.K. key, will enter into 
memory and change into AUTO mode) 
Reset 
Press and hold down all three keys ◄; O.K. and CL , 
will clear date, real time and microprocessor Switching 
programmes normally will not be affected. 
(Check by Read – Out; “?” mode) 
The 
mode is selected because date and real time 
must be programme new. 
Wiring diagrams SC 24 
SC 24.10 
 external key
Channel A - ON/OFF 
The external [ON/OFF] 
override has the same 
function as the channel 
A button on the front 
 Use same phase 
for external [ON/OFF], 
terminal No. 5 and 
terminal No. 2 only