Hanging Your Fan
Option 1:
Standard Ceiling Mounting
Figure 5
Figure 6
Follow the steps below to hang your fan
properly.
WARNING: To reduce the risk of shock, insure
electricity has been turned off at the circuit
breaker or fuse box before beginning.
NOTE: This ceiling fan is supplied with two
types of hanging assemblies; the standard ceiling
installation using the downrod with ball and
socket mounting, and the “close-to-ceiling”
mounting. The “close-to-ceiling” mounting is
recommended in rooms with less than 8-foot
ceilings or in areas where additional space is
desired from the oor to the fan blades.
When using standard downrod installation, the
distance from the ceiling to the bottom of the fan
blades will be approximately 11 inches. The
“close-to-ceiling” installation reduces the
distance from the ceiling to the bottom of the
fans blades to approximately 9 inches.
Once you have decided which ceiling installation
you will use, proceed with the following
instructions.
1. Remove the mounting bracket from the
canopy by loosening the four screws on the
top of the canopy. Remove the two non-
slotted screws and loosen the slotted screws
(Figure 5).
2. Install the hanger bracket by raising the
hander bracket to the UL listed electrical box
and securing with the 2 mounting screws.
3. Disassemble the downrod assembly before
passing the 120-volt supply wires through the
center hole in the ceiling hanger bracket as
shown in Figure 6.
4. Route the wires exiting the top of the fan
motor through the motor collar, motor collar
cap (wet fan only), the canopy bottom cover,
then the Ceiling Canopy. Make sure the slot
openings are on top. Route the wires through
the ball/downrod assembly (Figure 7).
5. Loosen, but do not remove the 2 set screws on
the collar on top of the motor housing.
6. Align the holes at the bottom of the downrod
with the holes in the collar on top of the
motor housing (Figure 8). Carefully insert
the collar pin through the holes in the collar
and downrod. Be careful not to jam the pin
against the wiring inside the downrod. Insert
the clevis pin and bend to ensure it is secure,
as noted in Figure 8.
7. Tighten the two screws on top of the fan
(Figure 8).
Figure 7
8002 ∙ 06/23/11 ∙ PCI