Use and Care Manual

9
NORSE Operating Manual & Parts List 9686006
GETTING STARTED
SAFETY / SPECIFICATIONS
ASSEMBLY / INSTALLATION
OPERATION
TROUBLESHOOTING
MAINTENANCE / REPAIR
TROUBLESHOOTING GUIDE
Symptom Possible Cause(s) Corrective Action
Motor will not run
Excessive dust in air
Excessive impeller noise
Excessive motor noise
Motor fails to develop full power
or motor stalls
Motor slow to start or
fails to reach full speed
Motor overheats
Tripping circuit breaker or fuses
1. Defective plug, cord, switch or motor
2. Blown fuse or circuit breaker
1. Leaking bag or hose connection
2. Filter or collector bag leaks
1. Large debris or piece of wood in im-
peller housing
2. Loose impeller
Defective motor
1. Low voltage to collector caused by
circuit overload
2. Low voltage to collector caused by
undersized extension cords
3. Low voltage from power source
1. Burned or defective motor
2. Defective motor capacitor switch
1. Motor overload
2. Improper motor cooling
1. Motor overloaded
2. Improper capacity of circuit breaker
or fuses
1. Check wiring, replace defective parts
2. Check fuse or breaker, replace
1. Check filter and collector bag connections.
Check collector hose connections
2. Dust trapped under bag clamp or collector bag
not sealed on flange
1. Do not vacuum metal materials. Turn collector
off and let debris settle in collector bag
2. Disconnect collector from power source. Re-
move connector and tighten impeller
Have motor checked by qualified motor service
technician
1. Remove other electric machines or appliances
from circuit
2. Increase wire gauge size of extension cords or
shorten extension cords
3. Request voltage check from power company
1. Check motor, replace if necessary
2. Check switch, replace if necessary
1. Reduce load by slowing dust production
2. Clean sawdust from motor
1. Reduce load by slowing dust production
2. Use proper capacity circuit breaker or fuse
9686006_oipm_En012_9643286.01 0318 03/07/18 Page 9